Shiinaha X-ray Tube Assembly oo la mid ah E7252X RAD14 soo saaraha iyo alaab-qeybiyaha |Sailray
X-ray Tube Assembly oo la mid ah E7252X RAD14

X-ray Tube Assembly oo la mid ah E7252X RAD14

X-ray Tube Assembly oo la mid ah E7252X RAD14

Sharaxaad Gaaban:

◆ Isku imaatinka tuubbada raajada ee dhammaan baaritaannada ogaanshaha joogtada ah ee leh xarumaha shucaaca caadiga ah ama dhijitaalka ah iyo kuwa fluoroscopic
◆Anode-xawaaraha-sare ee wareegga tuubada raajada
◆Qalabka la galiyo: 12° Rhenium-Tungsten molybdenum target (RTM)
◆Dhibcaha Focal: Yaryar 0.6, Weyn: 1.2
◆Korantada ugu badan ee tuubada: 150kV
◆Lagu dejiyay IEC60526 weelasha fiilooyinka korantada-sare ee nooca
Koronto dhaliyaha sare waa inuu waafaqsan yahay IEC60601-2-7
Kala soocidda IEC (IEC 60601-1: 2005): Qalabka I I ME

Faahfaahinta Alaabta

Shuruudaha Lacag-bixinta & Rarida:

Tags Product

Shuruucda, heerarka iyo xeerarka

Alaabtan waxa la soo saaray oo la horumariyay iyadoo la raacayo shuruucda, dardaaranka iyo xeerarka naqshadaynta:
◆ Amarka Golaha 93/42/EEC ee 14 Juun 1993 ee khuseeya aaladaha caafimaadka(Calaamadeynta CE).
TS EN ISO 13485 Qalabka caafimaadka - Nidaamyada maaraynta tayada - Shuruudaha sharciyeynta
ujeedooyin..
TS EN ISO 14971: 2012 Aaladaha caafimaadka - Codsiga maareynta halista aaladaha caafimaadka
TS EN ISO 15223-1 Aaladaha caafimaadka - Calaamadaha lagu isticmaalo calaamadaha aaladaha caafimaadka, summadaynta iyo macluumaadka la bixiyo - Qeybta 1: Shuruudaha guud
International Electrotechnical Commission (IEC), heerarkan soo socda ayaa si gaar ah loo tixgaliyaa.

Tixraaca caadiga ah

Tixraaca caadiga ah

Cinwaanada

EN 60601-2-54:2009 Qalabka korantada caafimaadka - Qeybta 2-54: Shuruudaha gaarka ah ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee qalabka raajada ee shucaaca iyo shucaaca
IEC60526 Fiilo koronto-sare leh iyo isku xirka godka qalabka raajada caafimaadka
IEC 60522:1999 Go'aaminta sifaynta joogtada ah ee isku dhafka tuubada raajada
IEC 60613-2010 Tilmaamaha korantada, kulaylka iyo rarista ee wareega wareega ee tuubooyinka raajada anode si loo ogaado cudurka
IEC60601-1: 2006 Qalabka korantada caafimaadka - Qeybta 1: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah
IEC 60601-1-3:2008 Qalabka korantada caafimaadka - Qeybta 1-3: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka muhiimka ah - Halbeegga dammaanadda: Ilaalinta shucaaca ee qalabka raajada ee ogaanshaha
IEC60601-2-28:2010 Qalabka korantada caafimaadka - Qeybta 2-28: Shuruudaha gaarka ah ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee shirarka tubbada raajada ee ogaanshaha caafimaadka
IEC 60336-2005 Qalabka korantada caafimaadka-Shirkadaha tuubbada raajada ee ogaanshaha caafimaadka - Astaamaha meelaha fog

Sharaxaada

● Magacaabistu waxay ka kooban tahay sidan soo socota:

MWHX7360

Tube

A

Socket danab sare leh oo jihada 90 darajo

MWTX73-0.6/1.2-150H

B

Socket danab sare leh oo jihada 270 darajo

Xogta Farsamada

Hanti

Tilmaamid

Heerka

Awood galinta magaca anode-ka

F 1

F 2

IEC 60613

20kW (50/60Hz)
30kW (150/180Hz
50kW (50/60Hz)
74kW (150/180Hz)
 

Awood kaydinta kulaylka Anode

212 kJ (300kHU)

IEC 60613

Awoodda qaboojinta ugu badan ee anode

750W

 
Awoodda kaydinta kulaylka

900kJ

 
Max.kulaylka joogtada ah oo aan lahayn Hawo-wareeg

180W

 
Maaddada anodeQalabka dahaarka sare ee Anode

Rhenium-Tungsten-TZM(RTM)

Rhenium-Tungsten-(RT)

 
Xagasha bartilmaameedka (Tixraac: dhidibka tixraaca)

12 °

IEC 60788

Isku dhafka tuubada raajada sifaynta dabiiciga ah

1.5 mm Al / 75kV

IEC 60601-1-3

Barta xudunta u ah qiimaha magaca (yada)

F1 (fiiri yar)

F2 (fiirin weyn)

IEC 60336

0.6

1.2

 
tuubada raajada danab magaceeduShucaacaFluoroscopic

150kV

125kV

IEC 60613

Xogta kululaynta cathode Max.hadda

danabka ugu badan

≈ / AC, <20 kHz

 

F1

F 2

 

5.4A

≈9V

5.4 A

≈17V

 
Shucaaca ka daadanaya 150 kV/3mA masaafo 1m ah

1.0mGy/h

IEC60601-1-3

Goobta shucaaca ugu badan

430×430mm at SID 1m
 
Culayska isku-ururinta tuubada raajada

Qiyaastii18 kg

 

Shuruudaha hawlgalka, kaydinta iyo gaadiidka

Xaddid

Xadka Hawlgalka

Xadka Gaadiidka iyo Kaydinta

Heerkulka deegaanka

Laga bilaabo 10ilaa 40

Laga bilaabo - 20to 70

Qoyaanka qaraabada

≤75%

≤93%

Cadaadiska Barometric

Laga soo bilaabo 70kPa ilaa 106kPa

Laga soo bilaabo 70kPa ilaa 106kPa

 

Stator qiyamka muhiimka ah

1-phase stator

Barta tijaabada

C-M

C-A

iska caabin dabaylaha

≈18.0…22.0Ω

≈45.0…55.0Ω

Ugu badnaan.

230V± 10%

Ku talin in danab shaqaynayo (kor u kac)

160V± 10%

Korontada bareegga

70VDC

Korantada orod-ku-soo-gaadhista

80Vrms

Danab ku shaqeeya fluoroscopy

20V-40Vrms

Wakhtiga kor-u-qaadista (waxay kuxirantahay nidaamka bilowga)

1.2s

Digniin

Digniin ku saabsan is dhexgalka raajada Generator

1.Guryaha Burburka
Weligaa ha gelinin in ka badan awoodda la qiimeeyay isku xirka tuubada raajada
Haddii awoodda wax gelinta ay ka badato qeexida tuubada, waxay sababtaa heerkulka ka sarreeya ee anode, geliso tuubada dhalada burburtay iyo ugu dambeyntii dhibaatooyinka halista ah ee soo socda oo ay ugu wacan tahay kicinta cadaadiska xad-dhaafka ah ee uumiga saliidda gudaha golaha guryaha.
Xaaladdan oo kale oo aad u daran taasoo keentay in guryuhu ay dillaacaan culeys ka badan, dab-damiska kulaylka badbaadada ma ilaalin karo tuubada raajada xitaa haddii ay shaqeyso
Qaybaha daboolaya guryaha ayaa dilaaca
Dhaawaca bini'aadamka oo ay ku jiraan gubasho ay sabab u tahay baxsashada saliidda kulul.
Shil dab oo ka dhashay bartilmaameedka anode ololaya.
Soo saaraha raajada waa inuu lahaadaa shaqo ilaalin ah oo maamusha awoodda wax gelinta si ay ugu jirto qeexitaanka tuubada.

2.Shaqo koronto
Si looga fogaado khatarta shoogga koronto, qalabkan waa in lagu xidhaa oo keliya sahayda leh dhulka difaaca.

 3.Lama ogola wax ka beddelka qalabkan!!

Digniin

Ka digtoonow in lagu dhex xidho Generator X-ray

1.Over Rating
Isku xirka tuubada raajada waa la jebin karaa iyadoo la marsado hal tallaal oo ka badan.
Fadlan si taxadar leh u akhri xaashida taariikhda farsamada oo raac tilmaamaha.

2.Shaandhaynta Joogtada ah
Tshaandhaynta guud iyo fogaanta u dhaxaysa barta X-ray-ga iyo jidhka bini'aadamka si sharci ah ayaa loo habeeyey.
They waa in loo hoggaansamo sharciga.

3.Badbaadada kulaylka Badbaadada
Isku-xidhka tubbada raajada ayaa leh badqabka kulaylka badbaadada si ay u mamnuucdo awood gelin dheeraad ah marka guriga tuubada uu gaaro heerkulka(80)fur-furan.
Furaha laguma talinayo in lagu xidho gariiradda stator ee wareegyada taxanaha ah.
Xataa haddii daaraduhu shaqeeyo, waligaa ha damin tamarta nidaamka.Cutubka qaboojinta waa in la hawlgeliyaa haddii lagu isticmaalo nidaamka.

4.Xaaladda lama filaanka ah
Isku-xidhka tubbada raajada ayaa laga yaabaa inay halis u noqoto inay si lama filaan ah u shaqeyso sababtoo ah joojinta nolosha ama fashilka. Haddii dhibaatooyinka halista ah ee ay sababto khatarta sare la filayo, waxaa lagaa codsanayaa inaad haysato qorshe degdeg ah si aad uga fogaato kiis noocaas ah.

5.Codsi Cusub
Haddii aad isticmaasho badeecada codsi cusub oo aan lagu xusin faahfaahintan ama nooc ka duwan raajo dhaliyaha, fadlan nala soo xidhiidh si aan u xaqiijino in la heli karo.

Ka digtoonaanta Hawlgalka

1 .X-ray Shucaacailaalinta

Alaabtani waxay buuxinaysaa shuruudaha IEC 60601-1-3.

Isku xirka tuubada raajada ayaa shaqada siida shucaaca raajada.

Saamaynta jireed ee laxidhiidha waxay u horseedi kartaa waxyeelo bukaanka, soosaarida nidaamku waa inay qaadaa ilaalin habboon si looga fogaado shucaaca ionization.

2.Dielectric 0il

Isku-xidhka tuubada raajada ayaa leh dielectric 0il oo ka kooban xasilloonida korantada sare.Maadaama ay sun u tahay caafimaadka aadanaha,haddii ay ka soo baxdo aagga aan xaddidnayn,waa in loo tuuraa sida soo socota xeerka deegaanka.

3 .Hawlgalka Jawiga

Isku-xidhka tubbada raajada looma oggola in lagu isticmaalo jawiga gaasta gubanaysa ama daxalaysa.

4.Hagaaji Tubada Hadda

Iyadoo ku xiran xaaladaha shaqada,waxa laga yaabaa in la beddelo sifooyinka filaha.

Isbeddelkan ayaa laga yaabaa inuu u saro kaco heerka sare ee soo-gaadhista tuubada raajada.

Si looga hortago in isku dhafka tuubada raajada ay waxyeelo gaarto,si joogto ah u hagaaji tuubada hadda socota.

Marka laga soo tago marka tuubada raajada ay leedahay dhib la'aanlisticmaalka waqtiga,hagaajinta hadda tuubada ayaa loo baahan yahay.

5.X-ray Tube Heer kulka Guryaha

Ha taaban tuubada raajada ee guriga wax yar uun ka dib qalliinka sababtoo ah heerkulka sare.

Joog tuubada raajada si loo qaboojiyo.

6Xadka hawlgalka

Kahor isticmaalka,fadlan xaqiiji in xaalada deegaanku ay ku dhex jirto Iimits.

7.Wax kasta oo cillad ah

P1ease la xidhiidh SAILRAY isla markiiba,Haddii wax cillad ah oo ka mid ah isku dhafka tuubada raajada la dareemo.

8.Qaadis

Isku-xidhka tubbada raajada iyo sidoo kale tubbada waxa ku jira walxo ay ka mid yihiin saliid iyo biro culus kuwaas oo deegaan ahaan u wanaagsan oo si habboon loo qubo iyadoo la raacayo qawaaniinta sharciga qaranka ee saxda ah waa in la hubiyaa. aqoonta farsamada ee loo baahan yahay oo dib u soo celin doonta tuubada raajada si loo tuuro.

Fadlan la xidhiidh adeegga macaamiisha ujeedadan.

Qalloocyada sii daaya ee cathode

MWHX7360 小焦点发射图
MWHX7360 大焦点发射图

Haddi(A) Barta Focal Yar

Haddi(A) Barta Focal Weyn

Kuleylinta iyo qaboojinta qalooca anode
Qalooca kululaynta iyo qaboojinta MWHX7360

Qallooca kululaynta iyo qaboojinta ee isku dhafka tuubada raajada

Tilmaamaha kulaylka Guriyeynta

Kululaynta iyo qaboojinta MWHX7360

Tuubada raajada sawiro cabbir cabbir ah

SRMWHX7360A

MWHX7360外形图

Isku shaandheynta iyo Qaybta Isku-tallaabta ee Dekedda

图片 27

Xidhiidhiyaha Rotor

图片 28

  • Hore:
  • Xiga:

  • Tirada Dalbashada Ugu Yar: 1pc

    Qiimaha: gorgortanka

    Faahfaahinta Baakadaha: 100pcs kartoonkiiba ama loo habeeyey iyadoo loo eegayo tirada

    Waqtiga Bixinta: 1 ~ 2 toddobaad iyadoo loo eegayo tirada

    Shuruudaha Lacag-bixinta: 100% T/T hore ama WESTERN UNION

    Awood bixinta: 1000pcs / bishii

    Halkan ku qor fariintaada oo noo soo dir