Shiinaha X-RAY TUBE U dhigma TOSHIBA E7242 Soo saaraha iyo Alaabta |Sailray
X-ray TUBE U dhigma TOSHIBA E7242

X-ray TUBE U dhigma TOSHIBA E7242

X-ray TUBE U dhigma TOSHIBA E7242

Sharaxaad Gaaban:

Codsiga: Isku xirka tuubada raajada ee dhammaan baaritaannada ogaanshaha joogtada ah ee caadiga ah
ama xarumaha shucaaca dhijitaalka ah iyo kuwa fluoroscopic
◆Qalabka la gelinayo: 12.5° Rhenium-Tungsten molybdenum target (RTM)
◆Dhibcaha Focal: Yaryar 0.6, Weyn: 1.2
◆Korantada ugu badan ee tuubada: 125kV
◆Lagu dejiyay IEC60526 weelasha fiilooyinka korantada-sare ee nooca
Koronto dhaliyaha sare waa inuu waafaqsan yahay IEC60601-2-7
Kala soocida IEC (IEC 60601-1: 2005): Qalabka I I

Faahfaahinta Alaabta

Shuruudaha Lacag-bixinta & Rarida:

Tags Product

Tixraaca caadiga ah

Tixraaca caadiga ah

Cinwaanada

EN 60601-2-54:2009 Qalabka korantada caafimaadka - Qeybta 2-54: Shuruudaha gaarka ah ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee qalabka raajada ee shucaaca iyo shucaaca
IEC60526 Fiilo koronto-sare leh iyo isku xirka godka qalabka raajada caafimaadka
IEC 60522:1999 Go'aaminta sifaynta joogtada ah ee isku dhafka tuubada raajada
IEC 60613-2010 Tilmaamaha korantada, kulaylka iyo rarista ee wareega wareega ee tuubooyinka raajada anode si loo ogaado cudurka
IEC60601-1: 2006 Qalabka korantada caafimaadka - Qeybta 1: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah
IEC 60601-1-3:2008 Qalabka korantada caafimaadka - Qeybta 1-3: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka muhiimka ah - Halbeegga dammaanadda: Ilaalinta shucaaca ee qalabka raajada ee ogaanshaha
IEC60601-2-28:2010 Qalabka korantada caafimaadka - Qeybta 2-28: Shuruudaha gaarka ah ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee shirarka tubbada raajada ee ogaanshaha caafimaadka
IEC 60336-2005 Qalabka korantada caafimaadka-Shirkadaha tuubbada raajada ee ogaanshaha caafimaadka - Astaamaha meelaha fog

Sharaxaada

● Magacaabistu waxay ka kooban tahay sidan soo socota:

MWHX7110A

Tube

A

Socket danab sare leh oo jihada 90 darajo

MWTX71-0.6/1.2-125

B

Socket danab sare leh oo jihada 270 darajo

Xogta Farsamada

Hanti

Tilmaamid

Heerka

Awood galinta magaca anode-ka

F 1

F 2

IEC 60613

20kW (50/60Hz)

40kW (50/60Hz)

 

Awood kaydinta kulaylka Anode

110 kJ (150kHU)

IEC 60613

Awoodda qaboojinta ugu badan ee anode

500W

 
Awoodda kaydinta kulaylka

900kJ

 
Max.kulaylka joogtada ah oo aan lahayn Hawo-wareeg

180W

 
Maaddada anodeQalabka dahaarka sare ee Anode

Rhenium-Tungsten-TZM(RTM)

Rhenium-Tungsten-(RT)

 
Xagasha bartilmaameedka (Tixraac: dhidibka tixraaca)

12.5 °

IEC 60788

Isku dhafka tuubada raajada sifaynta dabiiciga ah

1.5 mm Al / 75kV

IEC 60601-1-3

Barta xudunta u ah qiimaha magaca (yada)

F1 (fiiri yar)

F2 (fiirin weyn)

IEC 60336

0.6

1.2

 
tuubada raajada danab magaceeduShucaacaFluoroscopic

125kV

100kV

IEC 60613

Xogta kululaynta cathode Max.hadda

danabka ugu badan

≈ / AC, <20 kHz

 

F1

F 2

 

5.1A

≈79V

5.1 A

≈1214 V

 
Shucaaca ka daadanaya 150 kV/3mA masaafo 1m ah

0.5mGy/h

IEC60601-1-3

Goobta shucaaca ugu badan

443×443mm xaga SID 1m

 
Culayska isku-ururinta tuubada raajada

Qiyaastii18 kg

 

Shuruudaha hawlgalka, kaydinta iyo gaadiidka

Xaddid

Xadka Hawlgalka

Xadka Gaadiidka iyo Kaydinta

Heerkulka deegaanka

Laga bilaabo 10ilaa 40

Laga bilaabo - 20to 70

Qoyaanka qaraabada

≤75%

≤93%

Cadaadiska Barometric

Laga soo bilaabo 70kPa ilaa 106kPa

Laga soo bilaabo 70kPa ilaa 106kPa

 

Stator qiyamka muhiimka ah

1-phase stator

Barta tijaabada

C-M

C-A

iska caabin dabaylaha

≈18.0…22.0Ω

≈45.0…55.0Ω

Ugu badnaan.

230V± 10%

Ku talin in danab shaqaynayo (kor u kac)

160V± 10%

Korontada bareegga

70VDC

Korantada orod-ku-soo-gaadhista

80Vrms

Danab ku shaqeeya fluoroscopy

20V-40Vrms

Wakhtiga kor-u-qaadista (waxay kuxirantahay nidaamka bilowga)

1.2s

Ka digtoonaanta Hawlgalka

1 .X-ray Shucaacailaalinta

Alaabtani waxay buuxinaysaa shuruudaha IEC 60601-1-3.

Isku xirka tuubada raajada ayaa shaqada siida shucaaca raajada.

Saamaynta jireed ee laxidhiidha waxay u horseedi kartaa waxyeelo bukaanka, soosaarida nidaamku waa inay qaadaa ilaalin habboon si looga fogaado shucaaca ionization.

2.Dielectric 0il

Isku-xidhka tuubada raajada ayaa leh dielectric 0il oo ka kooban xasilloonida korantada sare.Maadaama ay sun u tahay caafimaadka aadanaha,haddii ay ka soo baxdo aagga aan xaddidnayn,waa in loo tuuraa sida soo socota xeerka deegaanka.

3 .Hawlgalka Jawiga

Isku-xidhka tubbada raajada looma oggola in lagu isticmaalo jawiga gaasta gubanaysa ama daxalaysa.

4.Hagaaji Tubada Hadda

Iyadoo ku xiran xaaladaha shaqada,waxa laga yaabaa in la beddelo sifooyinka filaha.

Isbeddelkan ayaa laga yaabaa inuu u saro kaco heerka sare ee soo-gaadhista tuubada raajada.

Si looga hortago in isku dhafka tuubada raajada ay waxyeelo gaarto,si joogto ah u hagaaji tuubada hadda socota.

Marka laga soo tago marka tuubada raajada ay leedahay dhib la'aanlisticmaalka waqtiga,hagaajinta hadda tuubada ayaa loo baahan yahay.

5.X-ray Tube Heer kulka Guryaha

Ha taaban tuubada raajada ee guriga wax yar uun ka dib qalliinka sababtoo ah heerkulka sare.

Joog tuubada raajada si loo qaboojiyo.

6Xadka hawlgalka

Kahor isticmaalka,fadlan xaqiiji in xaalada deegaanku ay ku dhex jirto Iimits.

7.Wax kasta oo cillad ah

P1ease la xidhiidh SAILRAY isla markiiba,Haddii wax cillad ah oo ka mid ah isku dhafka tuubada raajada la dareemo.

8.Qaadis

Isku-xidhka tubbada raajada iyo sidoo kale tubbada waxa ku jira walxo ay ka mid yihiin saliid iyo biro culus kuwaas oo deegaan ahaan u wanaagsan oo si habboon loo qubo iyadoo la raacayo qawaaniinta sharciga qaranka ee saxda ah waa in la hubiyaa. aqoonta farsamada ee loo baahan yahay oo dib u soo celin doonta tuubada raajada si loo tuuro.

Fadlan la xidhiidh adeegga macaamiisha ujeedadan.

Qalloocyada sii daaya ee cathode

图片

Haddi(A) Barta Focal Yar

图片1.2焦点

Haddi(A) Focal Spot Weyn

Keli iyo taxane loading

Xaaladaha: Voltage Tube Saddex- Waji

Soo noqnoqda Awoodda Stator 50Hz/60Hz

Ia (mA)

图片4

t(-yada)

Ia (mA)

图片3

t(-yada)

Kuleylinta iyo qaboojinta qalooca anode

  IEC60613

图片5

Qallooca kululaynta iyo qaboojinta ee isku dhafka tuubada raajada

Tilmaamaha kulaylka Guriyeynta

图片6

Tuubada raajada sawiro cabbir cabbir ah

SRMWHX7110A

图片7

Isku shaandheynta iyo Qaybta Isku-tallaabta ee Dekedda

图片 27

Xidhiidhiyaha Rotor

图片 28

  • Hore:
  • Xiga:

  • Tirada Dalbashada Ugu Yar: 1pc

    Qiimaha: gorgortanka

    Faahfaahinta Baakadaha: 100pcs kartoonkiiba ama loo habeeyey iyadoo loo eegayo tirada

    Waqtiga Bixinta: 1 ~ 2 toddobaad iyadoo loo eegayo tirada

    Shuruudaha Lacag-bixinta: 100% T/T hore ama WESTERN UNION

    Awood bixinta: 1000pcs / bishii

    Halkan ku qor fariintaada oo noo soo dir