Qalabka Guryaha ee Tuubada X-ray TOSHIBA E7239X
◆Ku-dubaridka tuubada raajada ee dhammaan baaritaannada ogaanshaha joogtada ah oo leh goobo shaqo oo caadi ah ama dhijitaal ah iyo kuwa fluoroscopic ah
◆Qaababka gelinta: 16° Rhenium-Tungsten molybdenum target (RTM)
◆ Meelaha diiradda la saarayo: Yar 1.0, Weyn: 2.0
◆Dabka ugu badan ee tuubada:125kV
◆La jaanqaaday fiilooyinka korantada sare leh ee nooca IEC60526
◆Matoorka danab-dhaliyaha sare waa inuu la jaanqaadaa IEC60601-2-7
◆Kala-soocidda IEC (IEC 60601-1:2005): Qalabka Fasalka I ME
Muraayadda Hoggaanka ee X-ray-ga ah 37 ZF3
Moodhka MAGACA: ZF3
U-dhignaanta Lead: 0.22mmpb
Cabbirka ugu badan: 2.4*1.2m
Cufnaanta: 4.46gm/Cm
Dhumucda: 8-150mm
Shahaadada: CE
Codsiga: Muraayadaha Hoggaanka ee Ilaalinta Shucaaca X-Ray ee Caafimaadka
Qalabka: Muraayadda Lead
Hufnaan: in ka badan 85%
Suuqyada Dhoofinta: Caalamka
Badhanka riixista X-ray Beddelka Microswitch-ka Omron Nooca HS-02-1
Moodel: HS-02-1
Nooca: Tallaabo keli ah
Dhismaha iyo agabka: Iyada oo leh badhanka yar ee Omron, daboolka fiilada isku xidhka PU iyo fiilooyinka naxaasta ah.
Waxaan helay oggolaanshaha CE ROHS
Dhererka fiilada waxaa loo habeyn karaa iyadoo loo eegayo shuruudaha kala duwan
Badhanka riixista X-ray Beddelka Farsamada Nooca 19 HS-01-1
Moodel: HS-01-1
Nooca: Tallaabo keli ah
Dhismaha iyo agabka: Iyada oo leh badhanka farsamada, daboolka fiilada gariiradda PU iyo fiilooyinka naxaasta ah
Waxaa lagu hagaajin karaa isku xirka rj11, rj12, rj45, DB9 iwm.
Dhererka fiilada waxaa loo habeyn karaa si loo daboolo baahiyaha iyo doorbidyada gaarka ah.
Ansixinta CE ROHS
Tuubada Sawirka Ilkaha ee Muuqaalka ah ee TOSHIBA D-051
Nooca: Tuubada raajada anode-ka ee aan istaagga lahayn
Codsiga: Qaybta raajo-raajada ilkaha ee dusha sare
Moodel: KL5A-0.5-105
U dhiganta TOSHIBA D-051
Tuubo galaas oo tayo sare leh oo isku dhafan
Tuubada X-ray-ga Ilkaha CEI OPX105
Nooca: Tuubada raajada ee anode-ka ee saldhigga
Codsiga: Qaybta raajo-raajada ilkaha ee dusha sare
Moodel: KL5-0.5-105
U dhiganta CEI OPX105
Tuubo galaas oo tayo sare leh oo isku dhafan
Tuubada X-ray-ga ee Moobaylka Cei OX110-5
Nooca: Tuubada raajada ee anode-ka ee saldhigga
Codsiga: Qaybta raajada guud ee ogaanshaha
Moodel: KL25-0.6/1.5-110
U dhiganta CEI OX110-5
Tuubo galaas oo tayo sare leh oo isku dhafan
Tuubada X-ray-ga Caafimaadka CEI OX105-6
Nooca: Tuubada raajada ee anode-ka ee saldhigga
Moodel: KL20-2.8-105
Codsiga: Qaybta raajada guud ee ogaanshaha
U dhiganta CEI OX105-6
Tuubo galaas oo tayo sare leh oo isku dhafan
Tuubada X-ray-ga Caafimaadka XD3A
Nooca: Tuubada raajada ee anode-ka ee saldhigga
Codsiga: Qaybta raajada guud ee ogaanshaha
Moodel: RT13A-2.6-100 oo u dhiganta XD3A-3.5/100
Tuubo galaas oo tayo sare leh oo isku dhafan
Tareenka X-ray-ga ee Moobaylka CEI 110-15
Nooca: Tuubada raajada ee anode-ka ee saldhigga
Codsiga: Qaybta raajada baarista guud ahaan waxaana loo heli karaa danab tuubo magac leh oo leh wareeg is-hagaajin ah.
Moodel: KL10-0.6/1.8-110
U dhiganta CEI 110-15
Tuubo galaas oo tayo sare leh oo isku dhafan
Tuubada X-ray-ga Ilkaha Xd2
Nooca: Tuubada raajada anode-ka ee aan istaagga lahayn
Codsiga: Qaybta raajada ilkaha ee afka laga qaato ama mashiinka raajada 10mA
Moodel: RT12-1.5-85
Tuubo galaas oo tayo sare leh oo isku dhafan
Tuubada X-ray-ga Ilkaha oo leh Shabaq
Nooca: Tuubada raajada ee anode-ka ee saldhigga
Codsiga: Qaybta raajada ilkaha ee afka laga qaato
Qaabka: KL2-0.8-70G
U dhiganta CEI OCX/65-G