Tixraaca caadiga ah | Cinwaanada |
EN 60601-2-54:2009 | Qalabka korantada caafimaadka - Qeybta 2-54: Shuruudaha gaarka ah ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee qalabka raajada ee shucaaca iyo shucaaca |
IEC60526 | Fiilo koronto-sare leh iyo isku xirka godka qalabka raajada caafimaadka |
IEC 60522:1999 | Go'aaminta sifaynta joogtada ah ee isku dhafka tuubada raajada |
IEC 60613-2010 | Tilmaamaha korantada, kulaylka iyo rarista ee wareega wareega ee tuubooyinka raajada anode si loo ogaado cudurka |
IEC60601-1: 2006 | Qalabka korantada caafimaadka - Qeybta 1: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah |
IEC 60601-1-3:2008 | Qalabka korantada caafimaadka - Qeybta 1-3: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka muhiimka ah - Halbeegga dammaanadda: Ilaalinta shucaaca ee qalabka raajada ee ogaanshaha |
IEC60601-2-28:2010 | Qalabka korantada caafimaadka - Qeybta 2-28: Shuruudaha gaarka ah ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee shirarka tubbada raajada ee ogaanshaha caafimaadka |
IEC 60336-2005 | Qalabka korantada caafimaadka-Shirkadaha tuubbada raajada ee ogaanshaha caafimaadka - Astaamaha meelaha fog |
● Magacaabistu waxay ka kooban tahay sidan soo socota:
MWHX7110A | Tube | A | Socket danab sare leh oo jihada 90 darajo |
MWTX71-0.6/1.2-125 | B | Socket danab sare leh oo jihada 270 darajo |
Hanti | Tilmaamid | Heerka | |
Awood galinta magaca anode-ka | F 1 | F 2 | IEC 60613 |
20kW (50/60Hz) | 40kW (50/60Hz) | ||
Awood kaydinta kulaylka Anode | 110 kJ (150kHU) | IEC 60613 | |
Awoodda qaboojinta ugu badan ee anode | 500W | ||
Awoodda kaydinta kulaylka | 900kJ | ||
Max. kulaylka joogtada ah oo aan lahayn Hawo-wareeg | 180W | ||
Maaddada anodeQalabka dahaarka sare ee Anode | Rhenium-Tungsten-TZM(RTM) Rhenium-Tungsten-(RT) | ||
Xagasha bartilmaameedka (Tixraac: dhidibka tixraaca) | 12.5 ° | IEC 60788 | |
Isku dhafka tuubada raajada sifaynta dabiiciga ah | 1.5 mm Al / 75kV | IEC 60601-1-3 | |
Barta xudunta u ah qiimaha magaca (yada) | F1 (fiiri yar) | F2 (fiirin weyn) | IEC 60336 |
0.6 | 1.2 | ||
tuubada raajada danab magaceeduShucaacaFluoroscopic | 125kV 100kV | IEC 60613 | |
Xogta kululaynta cathode Max. hadda danabka ugu badan | ≈ / AC, <20 kHz | ||
F1 | F 2 | ||
5.1A ≈7~9V | 5.1 A ≈12~14 V | ||
Shucaaca ka daadanaya 150 kV/3mA masaafo 1m ah | ≤0.5mGy/h | IEC60601-1-3 | |
Goobta shucaaca ugu badan | 443×443mm xaga SID 1m | ||
Culayska isku-ururinta tuubada raajada | Qiyaastii 18 kg |
Xaddid | Xadka Hawlgalka | Xadka Gaadiidka iyo Kaydinta |
Heerkulka deegaanka | Laga bilaabo 10℃ilaa 40℃ | Laga bilaabo - 20℃to 70℃ |
Qoyaanka qaraabada | ≤75% | ≤93% |
Cadaadiska Barometric | Laga soo bilaabo 70kPa ilaa 106kPa | Laga soo bilaabo 70kPa ilaa 106kPa |
1-phase stator
Barta tijaabada | C-M | C-A |
iska caabin dabaylaha | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
Ugu badnaan. | 230V± 10% | |
Ku talin in danab shaqaynayo (kor u kac) | 160V± 10% | |
Voltaga bareegga | 70VDC | |
Korantada orod-ku-soo-gaadhista | 80Vrms | |
Danab ku shaqeeya fluoroscopy | 20V-40Vrms | |
Wakhtiga kor-u-qaadista (waxay kuxirantahay nidaamka bilowga) | 1.2s |
1 .X-ray Shucaacailaalinta
Alaabtani waxay buuxinaysaa shuruudaha IEC 60601-1-3.
Isku xirka tuubada raajada ayaa shaqada siida shucaaca raajada.
Saamaynta jireed ee laxidhiidha waxay u horseedi kartaa waxyeelo bukaanka, soosaarida nidaamku waa inay qaadaa ilaalin habboon si looga fogaado shucaaca ionization.
2.Dielectric 0il
Isku-xidhka tuubada raajada ayaa leh dielectric 0il oo ka kooban xasilloonida korantada sare. Maadaama ay sun u tahay caafimaadka aadanaha,haddii ay soo baxdo aagga aan xaddidnayn,waa in loo tuuraa sida soo socota xeerka deegaanka.
3 .Hawlgalka Jawiga
Isku-xidhka tubbada raajada looma oggola in lagu isticmaalo jawiga gaasta gubanaysa ama daxalaysa.
4.Hagaaji Tubada Hadda
Iyadoo ku xiran xaaladaha shaqada,waxaa laga yaabaa in la beddelo sifooyinka filaha.
Isbeddelkan ayaa laga yaabaa inuu u saro kaco heerka sare ee soo-gaadhista tuubada raajada.
Si looga hortago in isku dhafka tuubada raajada ay waxyeelo gaarto,si joogto ah u hagaaji tuubada hadda socota.
Marka laga soo tago marka tuubada raajada ay leedahay dhib la'aanlisticmaalka waqtiga,hagaajinta hadda tuubada ayaa loo baahan yahay.
5.X-ray Tube Heer kulka Guryaha
Ha taaban tuubada raajada ee guriga wax yar uun ka dib qalliinka sababtoo ah heerkulka sare.
Joog tuubada raajada si loo qaboojiyo.
6Xadka hawlgalka
Kahor isticmaalka,fadlan xaqiiji in xaalada deegaanku ay ku dhex jirto Iimits.
7.Wixii cillad ah
P1ease la xidhiidh SAILRAY isla markiiba,Haddii wax cillad ah oo ka mid ah isku dhafka tuubada raajada la dareemo.
8.Qaadis
Isku-xidhka tubbada raajada iyo sidoo kale tubbada waxa ku jira walxo ay ka mid yihiin saliid iyo biro culus kuwaas oo deegaan ahaan u wanaagsan oo si habboon loo qubo si waafaqsan xeerarka sharciga qaranka ee jira waa in la hubiyaa. aqoonta farsamada ee loo baahan yahay oo dib u soo celin doonta tuubada raajada si loo tuuro.
Fadlan la xidhiidh adeegga macaamiisha ujeedadan.
Haddi(A) Barta Focal Yar
Haddi(A) Focal Spot Weyn
Xaaladaha: Voltage Tube Saddex- Waji
Soo noqnoqda Awoodda Stator 50Hz/60Hz
Ia (mA)
t(-yada)
Ia (mA)
t(-yada)
IEC60613
Tilmaamaha kulaylka Guriyeynta
SRMWHX7110A
Isku shaandheynta iyo Qaybta Isku-tallaabta ee Dekedda
Xidhiidhiyaha Rotor
Tirada Dalbashada Ugu Yar: 1pc
Qiimaha: gorgortanka
Faahfaahinta Baakadaha: 100pcs kartoonkiiba ama loo habeeyey iyadoo loo eegayo tirada
Waqtiga Bixinta: 1 ~ 2 toddobaad iyadoo loo eegayo tirada
Shuruudaha Lacag-bixinta: 100% T/T hore ama WESTERN UNION
Awood bixinta: 1000pcs / bishii