Tixraac heerka | Cinwaanada |
En 60601-2-54: 2009 | Qalabka korantada caafimaadka - Qeybta 2-54: Shuruudo gaar ah oo loogu talagalay badbaadada aasaasiga ah iyo waxqabadka daruuriga ah ee qalabka raajada ee qalabka radiography iyo shucaaca |
Iec60526 | Xiriirinta fiilada-sare ee korantada iyo xijaabka farsamada daaweynta ee caafimaadka |
IEC 60522: 1999 | Go'aaminta xarkaha joogtada ah ee ururka raajada-raajada |
IEC 60613-2010 | Korantada, kuleylka iyo astaamaha xamuulka ee ku saabsan jahwareerka tuubooyinka dareeraha ah ee loogu talagalay baaritaanka caafimaadka |
IEC60601-1: 2006 | Qalabka korantada caafimaadka - Qeybta 1: Shuruudaha guud ee amniga aasaasiga ah iyo waxqabadka muhiimka ah |
IEC 60601-1-3: 2008 | Qalabka korantada caafimaadka - Qeybta 1-3: Shuruudaha guud ee amniga aasaasiga ah iyo waxqabadka muhiimka ah - Heerka Aruubta - Shuruucda shucaaca: Ilaalinta shucaaca ee ku jirta qalabka 'raajada' |
Iec60601-28: 2010 | Qalabka korantada caafimaadka - Qeybta 2-28: Shuruudo gaar ah oo loogu talagalay badbaadada aasaasiga ah iyo waxqabadka muhiimka ah ee ururada raajada ee raajada-xajikada ah ee baaritaanka caafimaadka |
IEC 60336-2005 | Qalabka korantada ee daweynta-raajada-raajada-raajada-raaxada ee loogu talagalay isu-ururinta baarista caafimaadka - astaamaha dhibcaha focal |
● Magacaabistu waxay ka kooban tahay sida soo socota:
MWhx7110A | Tuubbo | A | Gethos sare oo leh 90 jiho digir |
Mwtx71-0.6/1.2-125 | B | Gethos-ka sare oo leh 270 jiho |
Hanti | Cayimid | Caadi ah | |
Awoodda dhiigga ee loo yaqaan 'Earfen' | F 1 | F 2 | IEC 60613 |
20kw (50 / 60hz) | 40kw (50 / 60hz) | ||
Awoodda kaydinta kuleylka | 110 KJ (150khu) | IEC 60613 | |
Awooda qaboojinta ugu badan ee anaga | 500W | ||
Awoodda kaydinta kuleylka | 900KJJ | ||
Max. Ku dheelitirida kuleylka joogtada ah ee aan lahayn hawo-mareenka | 180W | ||
Maaddada AnodeAreode dusha sare ee darada | Rhenium-Tungsten-Tzm (RTM) Rhenium-Tungsten- (RT) | ||
Xagal bartilmaameed (Re: tixraac tixraac) | 12.5 ° | IEC 607888 | |
X-Ray tuubada tuubada tuubada | 1.5 mm al / 75kv | IEC 60601-1-3 | |
XUQUUQDA ISTICMAALKA KHATARTA | F1 (diiradda yar) | F2 (diiradda weyn) | IEC 60336 |
0.6 | 1.2 | ||
X-raajada tuubbada tuubbadaIftiimiintaFluoriscopic | 125kv 1001kv | IEC 60613 | |
Xogta kululaynta cathode kuleylka Max. qul-qul Voltage Max | ≈ / AC, <20 khz | ||
F1 | F 2 | ||
5.1a ≈7~9V | 5.1 a ≈12~14 v | ||
Shucaaca shucaaca 150 kv / 3ma oo ku jirta masaafada 1m | ≤0.5MyGy / H | Iec60601-1-3 | |
Ugu badnaan shucaaca | 443 × 443mm at Sid 1m | ||
Miisaanka Shidaalka X-Ray TUBE | Qiyaastii. 18 kg |
Xadad | Xadka hawlgalka | Gaadiidka iyo xadadka kaydinta |
Heerkulka deegaanka | Laga bilaabo 10℃ilaa 40℃ | Laga soo bilaabo℃to 70℃ |
Qoyaan qaraabo ah | 75% | ≤93% |
Cadaadiska Barometric | Laga bilaabo 70kpa ilaa 106kpa | Laga bilaabo 70kpa ilaa 106kpa |
1-weji weji
Dhibic tijaabo ah | C-M | C-A |
Caabbitaanka Dabaysha | ≈18.0 ... 22.0ω | ≈45.0 ... 55.0ω |
Max.permate-ka Gawaarida Gawaarida (orodka) | 230V ± 10% | |
Kula tali korantada hawlgalka (orodka) | 160v ± 10% | |
Burburinta korantada | 70vdc | |
Orodka orodka-ku-soo-gaadhista | 80vrms | |
Ku orod-on korantada ee fluoroscopy | 20v-40vrms | |
Waqtiga orodka (waxay kuxirantahay nidaamka bilowga ah) | 1.2s |
1 .x-Ray Rayilaalinta
Shaygaani wuxuu fuliyaa shuruudaha IEC 60601-1-3.
Golaha 'raajada-raajka' raajadaaga '' raajada '' '' '' '' '' '' '' '' uu shaqeynayo. Sidaa darteed shaqaalaha tababaran oo u dhigma ayaa loo oggol yahay inay ku shaqeeyaan ururka raajada xijaabka.
Saamaynta cilmiga maskaxda ee la xiriira waxay u horseedi kartaa waxyeelo bukaanka, wax soo saarka nidaamka waa inuu qaataa difaac habboon si looga fogaado shucaaca IONation.
2.Dieltric 0il
Shirkadda X-Ray TUBE wuxuu leeyahay Dielectic 0il oo ku jira xasilloonida korantada sare. Sida sunta ah ee caafimaadka aadanaha,Haddii ay ku dhacdo aagga aan xadidan,Waa in la tuuraa sida ku xusan qaanuunka maxalliga ah.
3 .poperemere
X-Ray TUBE TUBE looma oggola in loo isticmaalo jawiga guban kara ama gaaska dambaysta ah ·
4.Hagaaji tuubada hada
Waxay kuxirantahay xaaladaha hawlgalka,Calaamadaha sharoobada ayaa la beddeli karaa.
Isbedelkani wuxuu u baahan karaa ka soo gaadhsiiya soo-gaadhista sicirka guud ee shirkadda raajada xiji.
Si looga hortago in raajada raajada raajada ah laga soo gaabiyo,Ku hagaaji tuubada si joogto ah.
Ka sokow marka raajada raajada ay dhibaato ku qabato dhibaatada alWaqtiga la adeegsado,hagaajinta tuubada tubada ayaa loo baahan yahay.
5.X-raajada guryaha ee raajada
Ha ku taaban dusha sare ee guryaha xargaha tuubada oo keliya qalliinka ka dib heerkulka sare awgeed.
Jooji tuubada raajada ee raaji si aad u qaboojiso.
6Xadka.
Kahor adeegsiga,Fadlan xaqiiji xaalada deegaanka ee deegaanka ay ku dhexjirto dadka hawlgalka ah.
7.
P1 Content Xiriir si aad u hesho Circmay,Haddii waxkasta oo ka mid ah goynta raajada xiji laguma arko.
8.Discosal
Golaha 'raajada' 'Ray TUBE' iyo sidoo kale tuubada ayaa ka kooban agab ay ka mid yihiin saliida iyo biraha culus ee loo yaqaan 'bey'adda'.
Fadlan la xiriir Adeegga Macaamiisha ujeedkan.
Haddii (a) Spot yar
Haddii (a) Spol Folt
Shuruudaha: tuubada tuubbada tuubbada saddex-weji
Xaraashka Power Awoodda 50hz/ 60hz
Ia (ma)
t (yaasha)
Ia (ma)
t (yaasha)
Iec60613
Astaamaha kuleylka guryaha
Srmwhwhx.110A
Shaandhada isugeynta iyo qaybta ka gudubka dekada
Contertoter Connector Conting
Tirada ugu yar ee amarrada: 1pc
Qiimaha: gorgortanka
Faahfaahinta baakadaha: 100pcs halkii kartoono ama loo habeeyay iyadoo loo eegayo tirada
Waqtiga Gaarsiinta: 1 ~ 2 toddobaad marka loo eego tirada
Shuruudaha Bixinta: 100% T / T Horusocod ama Western Union
Awoodda sahayda: 1000pcs / bishii