Qalabka Tuubada X-ray wuxuu la mid yahay E7252X RAD14

Qalabka Tuubada X-ray wuxuu la mid yahay E7252X RAD14

Qalabka Tuubada X-ray wuxuu la mid yahay E7252X RAD14

Sharaxaad Gaaban:

◆Ku-dubaridka tuubada raajada ee dhammaan baaritaannada ogaanshaha joogtada ah oo leh goobo shaqo oo caadi ah ama dhijitaal ah iyo kuwa fluoroscopic ah
◆Galinta tuubada raajo-ga ee anode-ka ah ee xawaaraha sare leh
◆Qaybaha la gelinayo waxaa ka mid ah: 12° Rhenium-Tungsten molybdenum target (RTM)
◆Meelo diiradda la saarayo: Yar 0.6, Weyn: 1.2
◆Danabka ugu badan ee tuubada: 150kV
◆La jaanqaaday fiilooyinka korantada sare leh ee nooca IEC60526
◆Matoorka danab-dhaliyaha sare waa inuu waafaqsanaadaa IEC60601-2-7
◆ Kala-soocidda IEC (IEC 60601-1:2005): Qalabka Fasalka I ME

Faahfaahinta Badeecada

Shuruudaha Lacag-bixinta iyo Dhoofinta:

Calaamadaha Alaabta

Sharciyo, heerar iyo qawaaniin

Badeecadan waxaa la soo saaray oo la sameeyay iyadoo la raacayo sharciyada, tilmaamaha iyo qawaaniinta naqshadeynta ee soo socda:
◆Tilmaamaha Golaha 93/42/EEC ee 14 Juun 1993 ee ku saabsan aaladaha caafimaadka(Calaamadda CE).
◆EN ISO 13485:2016 Qalabka caafimaadka—Nidaamyada maaraynta tayada—Shuruudaha sharciyeynta
ujeeddooyin..
◆EN ISO 14971:2012 Qalabka caafimaadka - Adeegsiga maaraynta khatarta aaladaha caafimaadka (ISO 14971:2007, Nooca la saxay 2007-10-01)
◆EN ISO15223-1:2012 Qalabka caafimaadka——Astaamaha loo isticmaalo calaamadaha qalabka caafimaadka, calaamadaynta iyo macluumaadka la bixinayo Qaybta 1: Shuruudaha guud
Guddiga Caalamiga ah ee Elektroteknolojiyadda (IEC), heerarka soo socda ayaa si gaar ah loo tixgeliyaa.

Tixraaca Caadiga ah

Tixraaca Caadiga ah

Cinwaanada

EN 60601-2-54:2009 Qalabka korontada caafimaadka - Qaybta 2-54: Shuruudo gaar ah oo loogu talagalay badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee qalabka raajada ee raajada iyo raajada
IEC60526 Fiilada fiilada danab sare leh iyo isku xirka godka ee qalabka raajada caafimaadka
IEC 60522: 1999 Go'aaminta shaandhaynta joogtada ah ee isku-darka tuubooyinka raajada X-ray
IEC 60613-2010 Astaamaha korontada, kulaylka iyo rarista ee tuubooyinka raajada anode ee wareegaya si loo ogaado caafimaad
IEC60601-1:2006 Qalabka korontada caafimaadka - Qaybta 1: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah
IEC 60601-1-3:2008 Qalabka korontada caafimaadka - Qaybta 1-3: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah - Heerka Dammaanadda: Ilaalinta shucaaca ee qalabka baaritaanka raajada
IEC60601-2-28:2010 Qalabka korontada caafimaadka - Qaybta 2-28: Shuruudo gaar ah oo loogu talagalay badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee qalabka tuubooyinka raajada ee loogu talagalay baaritaanka caafimaadka
IEC 60336-2005 Qalabka korontada caafimaadka - qalabka lagu sameeyo tuubooyinka raajada si loo ogaado cudurka - Astaamaha meelaha diiradda la saarayo

Sharaxaad

● Magacaabista waxaa loo sameeyay sidan soo socota:

MWHX7360

Tube

A

Godka danab sare leh oo leh jihada 90 digrii

MWTX73-0.6/1.2-150H

B

Godka danab sare leh oo leh jihada 270 digrii

Xogta Farsamada

Hantida

Faahfaahinta

Heerka Caadiga ah

Awoodda(yada) gelinta magacaaban ee anode-ka

F 1

F 2

IEC 60613

20kW (50/60Hz)
30kW (150/180Hz)
50kW (50/60Hz)
74kW (150/180Hz)
 

Awoodda kaydinta kulaylka ee anode

212 kJ (300kHU)

IEC 60613

Awoodda qaboojinta ugu badan ee anode-ka

750W

 
Awoodda kaydinta kulaylka

900kJ

 
Ugu badnaan kala-baxa kulaylka joogtada ah iyada oo aan lahayn wareeg hawo leh

180W

 
Walxaha anode-kaQalabka dahaadhka sare ee anode

Rhenium-Tungsten-TZM(RTM)

Rhenium-Tungsten-(RT)

 
Xagasha Bartilmaameedka (Tixraac: dhidibka tixraaca)

12 °

IEC 60788

Shaandhaynta asalka ah ee tuubada X-ray

1.5 mm Al / 75kV

IEC 60601-1-3

Qiimaha magac-bixinta ee barta diiradda la saarayo

F1 (diiradda yar)

F2 (diiradda weyn)

IEC 60336

0.6

1.2

 
Danabka magacaaban ee tuubada X-rayraajadaFluoroscopic

150kV

125kV

IEC 60613

Xogta ku saabsan kuleylka katooliga Ugu badnaan hadda

Danabka ugu badan

≈ /AC, < 20 kHz

 

F1

F 2

 

5.4A

≈9V

5.4 A

≈17V

 
Shucaaca daadashada ee 150 kV / 3mA masaafada 1m

1.0mGy/saacaddii

IEC60601-1-3

Goobta shucaaca ugu badan

430 × 430mm oo ku taal SID 1m
 
Miisaanka isu-imaatinka tuubada X-ray

Qiyaastii 18 kg

 

Xaaladaha hawlgalka, kaydinta iyo gaadiidka

Xadka

Xadka Hawlgalka

Xadka Gaadiidka iyo Kaydinta

Heerkulka deegaanka

Laga bilaabo 10ilaa 40

Laga bilaabo - 20to 70

Qoyaan qaraabo ah

≤75%

≤93%

Cadaadiska Barometricka

Laga bilaabo 70kPa ilaa 106kPa

Laga bilaabo 70kPa ilaa 106kPa

 

Qiimaha muhiimka ah ee Stator-ka

Stator-ka 1-waji

Barta tijaabada

C-M

C-A

Iska caabinta dabaysha

≈18.0…22.0Ω

≈45.0…55.0Ω

Danabka hawlgalka ugu badan ee la oggol yahay (socodka)

230V ± 10%

Ku talin danab shaqaynta (socodka)

160V ± 10%

Danabka biriiga

70VDC

Danab ku shaqeeya soo-gaadhista

80Vrms

Danabka ku shaqeeya fluoroscopy-ga

20V-40Vrms

Waqtiga shaqada (iyadoo ku xiran nooca bilowga ah)

1.2s

Digniin

Digniin ku saabsan is-dhexgalka matoorka X-ray

1. Burburka Guryaha
Weligaa ha gelin awoodda la qiimeeyay ee ku jirta isku-xirka tuubada X-ray-ga
Haddii awoodda gelinta ay dhaafto qeexitaanka tuubada, waxay sababtaa heerkulka xad-dhaafka ah ee anode-ka, geli burburka muraayadda tuubada iyo ugu dambeyntii dhibaatooyinka soo socda ee daran ee ay keento cadaadiska xad-dhaafka ah ee uumiga saliidda ee gudaha isku-xidhka guryaha.
Xaalad aad u daran oo keenta dillaac guriga ah oo ka dhasha culays xad dhaaf ah, badhanka kulaylka badbaadada ma ilaalin karo tuubada raajada X-ray xitaa haddii uu shaqeeyo.
Qaybaha shaabadaynta guryaha oo dillaaca.
Dhaawac bini'aadam oo ay ku jiraan gubasho ka dhalatay saliid kulul oo ka soo baxday.
Shil dab ah oo ka dhashay bartilmaameedka anode ee ololaya.
Matoorka X-ray waa inuu lahaadaa shaqo ilaalin ah oo maamusha awoodda gelinta si ay ugu jirto qeexitaanka tuubada.

2. Shoogga Korontada
Si looga fogaado khatarta shoogga korontada, qalabkani waa inuu ku xidhnaa oo keliya sahay leh dhul ilaalin leh.

 3.Wax ka beddel laguma samayn karo qalabkan!!

Digniino

Digniin ku saabsan is-dhexgalka Matoorka X-ray

1. Qiimaynta Ka Badan
Isku-dubaridka tuubada raajada waa la jebin karaa iyadoo la mariyo hal tallaal oo ka sarreeya kan la qiimeeyay.
Fadlan si taxaddar leh u akhri warqadaha taariikhda farsamada oo raac tilmaamaha.

2.Shaandhaynta Joogtada ah
TSifeynta guud iyo masaafada u dhaxaysa barta diiradda saarta raajada X-ray iyo jirka aadanaha si sharci ah ayaa loo nidaamiyaa.
Twaa in loo hoggaansamo xeerarka.

3.Beddelka Kulaylka Badbaadada
Isku-dubaridka tuubada raajada X-ray wuxuu leeyahay badhanka kulaylka badbaadada si loo mamnuuco korontada gelinta dheeraadka ah marka guriga tuubooyinku gaaro heerkulka(80)fur furan.
Beddelka laguma talinayo in lagu xiro gariiradda stator-ka ee wareegga taxanaha ah.
Xitaa haddii badhanka uu shaqeeyo, waligaa ha damin korontada nidaamka. Qalabka qaboojinta waa in la hawlgeliyaa haddii loo isticmaalo nidaamka.

4. Cilad lama filaan ah
Isku-dubaridka tuubooyinka raajada X-ray waxay yeelan karaan khatar ah inay si lama filaan ah u cilladoobaan sababtoo ah joojinta nolosha ama cillad. Haddii la filayo dhibaatooyinka daran ee ka dhasha khatarta kor ku xusan, waxaa lagaa codsanayaa inaad yeelato qorshe degdeg ah si aad uga fogaato kiiskaas oo kale.

5. Codsi Cusub
Haddii aad isticmaasho badeecada iyadoo la adeegsanayo codsi cusub oo aan lagu xusin qeexitaankan ama nooc kale oo matoor X-ray ah, fadlan nala soo xiriir si aad u xaqiijiso helitaankeeda.

Digniin ku saabsan Hawlgalka

1. Shucaaca X-rayilaalinta

Badeecadani waxay buuxisaa shuruudaha IEC 60601-1-3.

Qalabkan tuubada X-ray wuxuu soo saaraa shucaaca X-ray marka uu shaqeynayo. Sidaa darteed, shaqaale aqoon iyo tababaran oo keliya ayaa loo oggol yahay inay ku shaqeeyaan qalabka tuubada X-ray.

Saamaynta fiisiyoolajiyadeed ee khuseeya waxay waxyeello u geysan kartaa bukaanka, soo saarista nidaamku waa inay qaadataa ilaalin habboon si looga fogaado shucaaca ionization.

2. Dielectric 0il

Qalabka tuubada raajada X-ray wuxuu leeyahay 0il oo dielectric ah si loo helo xasillooni koronto oo sareysa. Maadaama uu sun u yahay caafimaadka aadanaha.haddii ay ku dhacdo aagga aan xaddidnaynwaa in loo hoggaansamaa sida ku xusan xeerarka deegaanka.

3. Jawiga Hawlgalka

Qalabka lagu rakibo tuubooyinka X-ray looma oggola in lagu isticmaalo jawiga gaaska guban kara ama daxalka leh

4.Hagaaji hadda tuubada

Iyadoo ku xiran xaaladaha hawlgalkasifooyinka fiilooyinka ayaa laga yaabaa inay isbeddelaan.

Isbeddelkani wuxuu u horseedi karaa soo-gaadhista xad-dhaafka ah ee tuubada X-ray-ga.

Si looga hortago in qalabka tuubada X-raygu uu dhaawacmosi joogto ah u hagaaji qulqulka tuubada.

Intaa waxaa dheer marka tuubada X-ray ay dhibaato ku haysato qaloocalisticmaalka waqtiga dheerhagaajinta qulqulka tuubada ayaa loo baahan yahay.

5Heerkulka Guryaha Tuubada X-ray

Ha ku taaban dusha sare ee tuubada X-ray-ga isla marka qalliinka la sameeyo heerkul sare awgiis.

Tuubada X-ray-ga ha la qaboojiyo.

6Xadka hawlgalka

Kahor isticmaalkafadlan hubi in xaaladda deegaanku ay ku jirto xadka hawlgalka.

7Cilad kasta

Fadlan isla markiiba la xiriir SAILRAYhaddii la arko cillad ku timaadda qalabka tuubada X-ray.

8. Tuuris

Isku-dubaridka tuubada X-ray iyo sidoo kale tuubada waxaa ku jira agab sida saliid iyo biraha culus oo loo baahan yahay in lagu hubiyo deegaanka u fiican iyo qashin-qubka saxda ah iyadoo la raacayo xeerarka sharciga qaranka ee ansaxka ah. Qashinka guriga ama warshadaha waa mamnuuc. Soo-saaruhu wuxuu leeyahay aqoonta farsamada ee loo baahan yahay wuxuuna dib u celin doonaa isku-dubaridka tuubada X-ray si loo tuuro.

Fadlan la xiriir adeegga macaamiisha si aad u hesho ujeeddadaas.

Qaloocyada qiiqa ee katoodka

MWHX7360 小焦点发射图
MWHX7360 大焦点发射图

Haddii (A) Meel Fog oo Yar

Haddii (A) Meel Fog oo Weyn

Qalooca kulaylinta iyo qaboojinta ee anode
Qalooca kuleylinta iyo qaboojinta ee MWHX7360

Qalooca kulaylinta iyo qaboojinta ee isku-darka tuubada X-ray

Astaamaha Kulaylka Guryaha

Kuleylka iyo Qaboojinta Guryaha ee MWHX7360

Sawirrada cabbirka ee isku-darka tuubada X-ray

SRMMHX7360A

MWHX7360外形图

Isku-dubaridka Shaandhaynta iyo Qaybta Isgoyska ee Dekedda

图片 27

Fiilooyinka Isku xirka Rotor

图片 28

  • Kii hore:
  • Xiga:

  • Tirada Dalabka Ugu Yar: 1pc

    Qiimaha: Gorgortanka

    Faahfaahinta Baakadaha: 100pcs kartoonkiiba ama loo habeeyey iyadoo loo eegayo tirada

    Waqtiga Bixinta: 1 ~ 2 toddobaad iyadoo loo eegayo tirada

    Shuruudaha Lacag-bixinta: 100% T/T horay loo sii bixiyay ama WESTERN UNION

    Awoodda Bixinta: 1000pcs/bishii

    Halkan ku qor fariintaada oo noo soo dir