Badeecadan waxaa la soo saaray oo la sameeyay iyadoo la raacayo sharciyada, tilmaamaha iyo qawaaniinta naqshadeynta ee soo socda:
◆Tilmaamaha Golaha 93/42/EEC ee 14 Juun 1993 ee ku saabsan aaladaha caafimaadka(Calaamadda CE).
◆EN ISO 13485:2016 Qalabka caafimaadka—Nidaamyada maaraynta tayada—Shuruudaha sharciyeynta
ujeeddooyin..
◆EN ISO 14971:2012 Qalabka caafimaadka - Adeegsiga maaraynta khatarta aaladaha caafimaadka (ISO 14971:2007, Nooca la saxay 2007-10-01)
◆EN ISO15223-1:2012 Qalabka caafimaadka——Astaamaha loo isticmaalo calaamadaha qalabka caafimaadka, calaamadaynta iyo macluumaadka la bixinayo Qaybta 1: Shuruudaha guud
◆Guddiga Caalamiga ah ee Elektroteknolojiyadda (IEC), heerarka soo socda ayaa si gaar ah loo tixgeliyaa.
| Tixraaca Caadiga ah | Cinwaanada |
| EN 60601-2-54:2009 | Qalabka korontada caafimaadka - Qaybta 2-54: Shuruudo gaar ah oo loogu talagalay badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee qalabka raajada ee raajada iyo raajada |
| IEC60526 | Fiilada fiilada danab sare leh iyo isku xirka godka ee qalabka raajada caafimaadka |
| IEC 60522: 1999 | Go'aaminta shaandhaynta joogtada ah ee isku-darka tuubooyinka raajada X-ray |
| IEC 60613-2010 | Astaamaha korontada, kulaylka iyo rarista ee tuubooyinka raajada anode ee wareegaya si loo ogaado caafimaad |
| IEC60601-1:2006 | Qalabka korontada caafimaadka - Qaybta 1: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah |
| IEC 60601-1-3:2008 | Qalabka korontada caafimaadka - Qaybta 1-3: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah - Heerka Dammaanadda: Ilaalinta shucaaca ee qalabka baaritaanka raajada |
| IEC60601-2-28:2010 | Qalabka korontada caafimaadka - Qaybta 2-28: Shuruudo gaar ah oo loogu talagalay badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee qalabka tuubooyinka raajada ee loogu talagalay baaritaanka caafimaadka |
| IEC 60336-2005 | Qalabka korontada caafimaadka - qalabka lagu sameeyo tuubooyinka raajada si loo ogaado cudurka - Astaamaha meelaha diiradda la saarayo |
● Magacaabista waxaa loo sameeyay sidan soo socota:
| MWHX7360 | Tube | A | Godka danab sare leh oo leh jihada 90 digrii |
| MWTX73-0.6/1.2-150H | B | Godka danab sare leh oo leh jihada 270 digrii |
| Hantida | Faahfaahinta | Heerka Caadiga ah | |
| Awoodda(yada) gelinta magacaaban ee anode-ka | F 1 | F 2 | IEC 60613 |
| 20kW (50/60Hz) 30kW (150/180Hz) | 50kW (50/60Hz) 74kW (150/180Hz) | ||
| Awoodda kaydinta kulaylka ee anode | 212 kJ (300kHU) | IEC 60613 | |
| Awoodda qaboojinta ugu badan ee anode-ka | 750W | ||
| Awoodda kaydinta kulaylka | 900kJ | ||
| Ugu badnaan kala-baxa kulaylka joogtada ah iyada oo aan lahayn wareeg hawo leh | 180W | ||
| Walxaha anode-kaQalabka dahaadhka sare ee anode | Rhenium-Tungsten-TZM(RTM) Rhenium-Tungsten-(RT) | ||
| Xagasha Bartilmaameedka (Tixraac: dhidibka tixraaca) | 12 ° | IEC 60788 | |
| Shaandhaynta asalka ah ee tuubada X-ray | 1.5 mm Al / 75kV | IEC 60601-1-3 | |
| Qiimaha magac-bixinta ee barta diiradda la saarayo | F1 (diiradda yar) | F2 (diiradda weyn) | IEC 60336 |
| 0.6 | 1.2 | ||
| Danabka magacaaban ee tuubada X-rayraajadaFluoroscopic | 150kV 125kV | IEC 60613 | |
| Xogta ku saabsan kuleylka katooliga Ugu badnaan hadda Danabka ugu badan | ≈ /AC, < 20 kHz | ||
| F1 | F 2 | ||
| 5.4A ≈9V | 5.4 A ≈17V | ||
| Shucaaca daadashada ee 150 kV / 3mA masaafada 1m | ≤1.0mGy/saacaddii | IEC60601-1-3 | |
| Goobta shucaaca ugu badan |
430 × 430mm oo ku taal SID 1m | ||
| Miisaanka isu-imaatinka tuubada X-ray | Qiyaastii 18 kg | ||
| Xadka | Xadka Hawlgalka | Xadka Gaadiidka iyo Kaydinta |
| Heerkulka deegaanka | Laga bilaabo 10℃ilaa 40℃ | Laga bilaabo - 20℃to 70℃ |
| Qoyaan qaraabo ah | ≤75% | ≤93% |
| Cadaadiska Barometricka | Laga bilaabo 70kPa ilaa 106kPa | Laga bilaabo 70kPa ilaa 106kPa |
Stator-ka 1-waji
| Barta tijaabada | C-M | C-A |
| Iska caabinta dabaysha | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
| Danabka hawlgalka ugu badan ee la oggol yahay (socodka) | 230V ± 10% | |
| Ku talin danab shaqaynta (socodka) | 160V ± 10% | |
| Danabka biriiga | 70VDC | |
| Danab ku shaqeeya soo-gaadhista | 80Vrms | |
| Danabka ku shaqeeya fluoroscopy-ga | 20V-40Vrms | |
| Waqtiga shaqada (iyadoo ku xiran nooca bilowga ah) | 1.2s | |
Digniin ku saabsan is-dhexgalka matoorka X-ray
1. Burburka Guryaha
Weligaa ha gelin awoodda la qiimeeyay ee ku jirta isku-xirka tuubada X-ray-ga
Haddii awoodda gelinta ay dhaafto qeexitaanka tuubada, waxay sababtaa heerkulka xad-dhaafka ah ee anode-ka, geli burburka muraayadda tuubada iyo ugu dambeyntii dhibaatooyinka soo socda ee daran ee ay keento cadaadiska xad-dhaafka ah ee uumiga saliidda ee gudaha isku-xidhka guryaha.
Xaalad aad u daran oo keenta dillaac guriga ah oo ka dhasha culays xad dhaaf ah, badhanka kulaylka badbaadada ma ilaalin karo tuubada raajada X-ray xitaa haddii uu shaqeeyo.
*Qaybaha shaabadaynta guryaha oo dillaaca.
*Dhaawac bini'aadam oo ay ku jiraan gubasho ka dhalatay saliid kulul oo ka soo baxday.
*Shil dab ah oo ka dhashay bartilmaameedka anode ee ololaya.
Matoorka X-ray waa inuu lahaadaa shaqo ilaalin ah oo maamusha awoodda gelinta si ay ugu jirto qeexitaanka tuubada.
2. Shoogga Korontada
Si looga fogaado khatarta shoogga korontada, qalabkani waa inuu ku xidhnaa oo keliya sahay leh dhul ilaalin leh.
3.Wax ka beddel laguma samayn karo qalabkan!!
Digniin ku saabsan is-dhexgalka Matoorka X-ray
1. Qiimaynta Ka Badan
Isku-dubaridka tuubada raajada waa la jebin karaa iyadoo la mariyo hal tallaal oo ka sarreeya kan la qiimeeyay.
Fadlan si taxaddar leh u akhri warqadaha taariikhda farsamada oo raac tilmaamaha.
2.Shaandhaynta Joogtada ah
TSifeynta guud iyo masaafada u dhaxaysa barta diiradda saarta raajada X-ray iyo jirka aadanaha si sharci ah ayaa loo nidaamiyaa.
Twaa in loo hoggaansamo xeerarka.
3.Beddelka Kulaylka Badbaadada
Isku-dubaridka tuubada raajada X-ray wuxuu leeyahay badhanka kulaylka badbaadada si loo mamnuuco korontada gelinta dheeraadka ah marka guriga tuubooyinku gaaro heerkulka(80℃)fur furan.
Beddelka laguma talinayo in lagu xiro gariiradda stator-ka ee wareegga taxanaha ah.
Xitaa haddii badhanka uu shaqeeyo, waligaa ha damin korontada nidaamka. Qalabka qaboojinta waa in la hawlgeliyaa haddii loo isticmaalo nidaamka.
4. Cilad lama filaan ah
Isku-dubaridka tuubooyinka raajada X-ray waxay yeelan karaan khatar ah inay si lama filaan ah u cilladoobaan sababtoo ah joojinta nolosha ama cillad. Haddii la filayo dhibaatooyinka daran ee ka dhasha khatarta kor ku xusan, waxaa lagaa codsanayaa inaad yeelato qorshe degdeg ah si aad uga fogaato kiiskaas oo kale.
5. Codsi Cusub
Haddii aad isticmaasho badeecada iyadoo la adeegsanayo codsi cusub oo aan lagu xusin qeexitaankan ama nooc kale oo matoor X-ray ah, fadlan nala soo xiriir si aad u xaqiijiso helitaankeeda.
1. Shucaaca X-rayilaalinta
Badeecadani waxay buuxisaa shuruudaha IEC 60601-1-3.
Qalabkan tuubada X-ray wuxuu soo saaraa shucaaca X-ray marka uu shaqeynayo. Sidaa darteed, shaqaale aqoon iyo tababaran oo keliya ayaa loo oggol yahay inay ku shaqeeyaan qalabka tuubada X-ray.
Saamaynta fiisiyoolajiyadeed ee khuseeya waxay waxyeello u geysan kartaa bukaanka, soo saarista nidaamku waa inay qaadataa ilaalin habboon si looga fogaado shucaaca ionization.
2. Dielectric 0il
Qalabka tuubada raajada X-ray wuxuu leeyahay 0il oo dielectric ah si loo helo xasillooni koronto oo sareysa. Maadaama uu sun u yahay caafimaadka aadanaha.,haddii ay ku dhacdo aagga aan xaddidnayn,waa in loo hoggaansamaa sida ku xusan xeerarka deegaanka.
3. Jawiga Hawlgalka
Qalabka lagu rakibo tuubooyinka X-ray looma oggola in lagu isticmaalo jawiga gaaska guban kara ama daxalka leh
4.Hagaaji hadda tuubada
Iyadoo ku xiran xaaladaha hawlgalka,sifooyinka fiilooyinka ayaa laga yaabaa inay isbeddelaan.
Isbeddelkani wuxuu u horseedi karaa soo-gaadhista xad-dhaafka ah ee tuubada X-ray-ga.
Si looga hortago in qalabka tuubada X-raygu uu dhaawacmo,si joogto ah u hagaaji qulqulka tuubada.
Intaa waxaa dheer marka tuubada X-ray ay dhibaato ku haysato qaloocalisticmaalka waqtiga dheer,hagaajinta qulqulka tuubada ayaa loo baahan yahay.
5Heerkulka Guryaha Tuubada X-ray
Ha ku taaban dusha sare ee tuubada X-ray-ga isla marka qalliinka la sameeyo heerkul sare awgiis.
Tuubada X-ray-ga ha la qaboojiyo.
6Xadka hawlgalka
Kahor isticmaalka,fadlan hubi in xaaladda deegaanku ay ku jirto xadka hawlgalka.
7Cilad kasta
Fadlan isla markiiba la xiriir SAILRAY,haddii la arko cillad ku timaadda qalabka tuubada X-ray.
8. Tuuris
Isku-dubaridka tuubada X-ray iyo sidoo kale tuubada waxaa ku jira agab sida saliid iyo biraha culus oo loo baahan yahay in lagu hubiyo deegaanka u fiican iyo qashin-qubka saxda ah iyadoo la raacayo xeerarka sharciga qaranka ee ansaxka ah. Qashinka guriga ama warshadaha waa mamnuuc. Soo-saaruhu wuxuu leeyahay aqoonta farsamada ee loo baahan yahay wuxuuna dib u celin doonaa isku-dubaridka tuubada X-ray si loo tuuro.
Fadlan la xiriir adeegga macaamiisha si aad u hesho ujeeddadaas.
Haddii (A) Meel Fog oo Yar
Haddii (A) Meel Fog oo Weyn
Astaamaha Kulaylka Guryaha
SRMMHX7360A
Isku-dubaridka Shaandhaynta iyo Qaybta Isgoyska ee Dekedda
Fiilooyinka Isku xirka Rotor
Tirada Dalabka Ugu Yar: 1pc
Qiimaha: Gorgortanka
Faahfaahinta Baakadaha: 100pcs kartoonkiiba ama loo habeeyey iyadoo loo eegayo tirada
Waqtiga Bixinta: 1 ~ 2 toddobaad iyadoo loo eegayo tirada
Shuruudaha Lacag-bixinta: 100% T/T horay loo sii bixiyay ama WESTERN UNION
Awoodda Bixinta: 1000pcs/bishii