    Ku habboon qalabka baaritaanka raajada X-ray ee caadiga ah oo leh danab tuubo oo ah 150kV
    Goobta shucaaca X-ray waa leydi
     U hoggaansan heerarka qaranka iyo warshadaha ee khuseeya
     Cabbir yar
    Kalsooni sare iyo waxqabad kharash sare leh
    Isticmaalka saddex lakab iyo laba qaybood oo caleemo rasaas ah iyo qaab-dhismeed gaar ah oo ilaalin gudaha ah si loo ilaaliyo raajada X-ray
     Hagaajinta goobta shucaaca waa mid gacanta lagu sameeyo, goobta shucaaca waa mid si joogto ah loo hagaajin karo
     Goobta iftiinka ee la arki karo waxay qaadataa nalalka LED-ka ee dhalaalaya sare leh
     Wareegga dib u dhigista gudaha ayaa si toos ah u damin kara nalka 30 ilbiriqsi ka dib iftiin, wuxuuna gacanta ku damin karaa nalka inta lagu jiro xilliga iftiinka si loo dheereeyo cimriga nalka loona badbaadiyo tamarta.
    Xiriir farsamo oo ku habboon oo lagu kalsoonaan karo oo leh tuubada X-ray, oo si fudud loo hagaajin karo

  • Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka Xaddidaadda shucaaca X-ray-ga SR302

    Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka Xaddidaadda shucaaca X-ray-ga SR302

    Ku habboon qalabka baaritaanka raajada X-ray ee caadiga ah oo leh danab tuubo oo ah 150kV
    Goobta shucaaca X-ray waa leydi
     U hoggaansan heerarka qaranka iyo warshadaha ee khuseeya
     Cabbir yar
    Kalsooni sare iyo waxqabad kharash sare leh
    Isticmaalka lakab labanlaab ah iyo laba qaybood oo caleemo rasaas ah iyo qaab-dhismeed gaar ah oo ilaalin gudaha ah si loo ilaaliyo raajada X-ray
     Hagaajinta goobta shucaaca waa mid gacanta lagu sameeyo, goobta shucaaca waa mid si joogto ah loo hagaajin karo
     Goobta iftiinka ee la arki karo waxay qaadataa nalalka LED-ka ee dhalaalaya sare leh
     Wareegga dib u dhigista gudaha ayaa si toos ah u damin kara nalka 30 ilbiriqsi ka dib iftiin, wuxuuna gacanta ku damin karaa nalka inta lagu jiro xilliga iftiinka si loo dheereeyo cimriga nalka loona badbaadiyo tamarta.
    Xiriir farsamo oo ku habboon oo lagu kalsoonaan karo oo leh tuubada X-ray, oo si fudud loo hagaajin karo

  • Collimator-ka Caafimaadka ee X-ray Collimator-ka ee Tooska ah ee X-ray Collimator SR301

    Collimator-ka Caafimaadka ee X-ray Collimator-ka ee Tooska ah ee X-ray Collimator SR301

    Astaamaha
    Ku habboon danabka tuubada 150kV, qalabka baaritaanka raajada DR iyo kuwa caadiga ah
    Goobta shucaaca X-ray waa leydi
     U hoggaansan heerarka qaranka iyo warshadaha ee khuseeya
    Kalsooni sare iyo waxqabad kharash sare leh
     Lakabyo laba jibbaaran iyo laba qaybood oo caleemo rasaas ah iyo qaab-dhismeed gaar ah oo gudaha ah ayaa loo isticmaalaa in lagu ilaaliyo raajooyinka X-ray. Caleenta rasaasta sare waxay geli kartaa daaqadda tuubada raajada X-ray, taasoo si wax ku ool ah u ilaalin karta fallaaraha kala firdhisan.
     Hagaajinta goobta shucaaca waa mid gacanta lagu sameeyo, si joogto ah ayaa loo hagaajin karaa
     Goobta iftiinka ee la arki karo waxay qaadataa nalalka LED-ka ee dhalaalaya sare leh
     Wareegga dib u dhigista gudaha ayaa si toos ah u damin kara nalka 30 ilbiriqsi ka dib iftiin, wuxuuna gacanta ku damin karaa nalka inta lagu jiro xilliga iftiinka si loo dheereeyo cimriga nalka loona badbaadiyo tamarta.
    Xiriir farsamo oo ku habboon oo lagu kalsoonaan karo oo leh tuubada X-ray, oo si fudud loo hagaajin karo

  • Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka X-ray Collimator SR103

    Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka X-ray Collimator SR103

    Astaamaha
    Ku habboon qalabka baaritaanka raajada ee moobaylka ama la qaadi karo oo leh danab tuubo ah oo ah 120kV
    Goobta shucaaca X-ray waa leydi
     U hoggaansan heerarka qaranka iyo warshadaha ee khuseeya
     Cabbir yar
    Kalsooni sare iyo waxqabad kharash sare leh
    Isticmaalka hal lakab iyo laba qaybood oo caleemo rasaas ah iyo qaab-dhismeed gaar ah oo ilaalin gudaha ah si loo ilaaliyo raajada X-ray
     Hagaajinta goobta shucaaca waa mid gacanta lagu sameeyo, goobta shucaaca waa mid si joogto ah loo hagaajin karo
     Goobta iftiinka ee la arki karo waxay qaadataa nalalka LED-ka ee dhalaalaya sare leh
    Xiriir farsamo oo ku habboon oo lagu kalsoonaan karo oo leh tuubada X-ray, oo si fudud loo hagaajin karo

  • Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka Xaddidaadda shucaaca X-ray-ga SR202

    Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka Xaddidaadda shucaaca X-ray-ga SR202

    Astaamaha
     La jaanqaadi kara qalabka baaritaanka raajada X-ray iyadoo la adeegsanayo danab tuubo 150kV ah, oo ay ku jiraan nidaamyada dijitaalka ah ee DR iyo nidaamyada caadiga ah
    Goobta shucaaca X-ray waa leydi
     U hoggaansan heerarka qaranka iyo warshadaha ee khuseeya
     Cabbir yar
    Kalsooni sare iyo waxqabad kharash sare leh
    Waxay isticmaashaa hal lakab, laba qaybood oo caleemo rasaas ah iyo naqshad gaar ah oo ilaalin gudaha ah si ay u xirto raajada X-ray.
     Hagaajinta goobta shucaaca waa mid gacanta lagu sameeyo, si joogto ah ayaa loo hagaajin karaa
     Goobta iftiinka ee la arki karo waxay qaadataa nalalka LED-ka
     Wareeg dib u dhac ah oo ku dhex jira ayaa si toos ah u damiya laambadda 30 ilbiriqsi ka dib marka la hawlgeliyo, waxaana sidoo kale la heli karaa ikhtiyaar gacan-ku-dhigis ah oo lagu damin karo laambadda inta lagu jiro shaqada. Astaamahan waxaa loogu talagalay inay kordhiyaan cimriga nalka oo ay yareeyaan isticmaalka tamarta.

  • Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka X-ray Collimator SR102

    Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka X-ray Collimator SR102

    Astaamaha
    Ku habboon qalabka baaritaanka raajada X-ray ee caadiga ah oo leh danab tuubo ah oo ah 150kV
    Aagga ay sawirtay raajo X-ray waa leydi.
     Badeecadani waxay u hoggaansan tahay heerarka qaranka iyo warshadaha ee khuseeya
     Cabbir yar
    Waxqabad la isku halleyn karo, kharash-ool ah.
    Isticmaalka hal lakab iyo laba qaybood oo caleemo rasaas ah iyo qaab-dhismeed gaar ah oo ilaalin gudaha ah si loo ilaaliyo raajada X-ray
     Hagaajinta goobta shucaaca waa mid gacanta lagu sameeyo, goobta shucaaca waa mid si joogto ah loo hagaajin karo
     Goobta iftiinka ee muuqata waxay qaadataa nalalka LED-ka ee dhalaalaya oo heer sare ah, kuwaas oo leh cimri dheer oo adeeg ah.
     Wareegga dib u dhigista gudaha ayaa si toos ah u damin kara nalka 30 ilbiriqsi ka dib iftiin, wuxuuna gacanta ku damin karaa nalka inta lagu jiro xilliga iftiinka si loo dheereeyo cimriga nalka loona badbaadiyo tamarta.
    Xiriirka farsamada ee u dhexeeya badeecadan iyo tuubada X-ray waa mid ku habboon oo lagu kalsoonaan karo, hagaajintana waa mid fudud