Alaabtan waxa la soo saaray oo la horumariyay iyadoo la raacayo shuruucda, dardaaranka iyo xeerarka naqshadaynta:
◆ Amarka Golaha 93/42/EEC ee 14 Juun 1993 ee khuseeya aaladaha caafimaadka(Calaamadeynta CE).
TS EN ISO 13485 Qalabka caafimaadka - Nidaamyada maaraynta tayada - Shuruudaha sharciyeynta
ujeedooyin..
TS EN ISO 14971: 2012 Aaladaha caafimaadka - Codsiga maareynta khatarta aaladaha caafimaadka
TS EN ISO 15223-1 Aaladaha caafimaadka - Calaamadaha lagu isticmaalo calaamadaha aaladaha caafimaadka, summadaynta iyo macluumaadka la bixiyo - Qeybta 1: Shuruudaha guud
◆International Electrotechnical Commission (IEC), heerarkan soo socda ayaa si gaar ah loo tixgaliyaa.
Tixraaca caadiga ah | Cinwaanada |
EN 60601-2-54:2009 | Qalabka korantada caafimaadka - Qeybta 2-54: Shuruudaha gaarka ah ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee qalabka raajada ee shucaaca iyo shucaaca |
IEC60526 | Fiilo koronto-sare leh iyo isku xirka godka qalabka raajada caafimaadka |
IEC 60522:1999 | Go'aaminta sifaynta joogtada ah ee isku dhafka tuubada raajada |
IEC 60613-2010 | Tilmaamaha korantada, kulaylka iyo rarista ee wareega wareega ee tuubooyinka raajada anode si loo ogaado cudurka |
IEC60601-1: 2006 | Qalabka korantada caafimaadka - Qeybta 1: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah |
IEC 60601-1-3:2008 | Qalabka korantada caafimaadka - Qeybta 1-3: Shuruudaha guud ee badbaadada aasaasiga ah iyo waxqabadka muhiimka ah - Halbeegga dammaanadda: Ilaalinta shucaaca ee qalabka raajada ee ogaanshaha |
IEC60601-2-28:2010 | Qalabka korantada caafimaadka - Qeybta 2-28: Shuruudaha gaarka ah ee badbaadada aasaasiga ah iyo waxqabadka lagama maarmaanka ah ee shirarka tubbada raajada ee ogaanshaha caafimaadka |
IEC 60336-2005 | Qalabka korantada caafimaadka-Shirkadaha tuubbada raajada ee ogaanshaha caafimaadka - Astaamaha meelaha fog |
● Magacaabistu waxay ka kooban tahay sidan soo socota:
MWHX7010 | Tube | A | Socket danab sare leh oo jihada 90 darajo |
MWTX70-1.0/2.0-125 | B | Socket danab sare leh oo jihada 270 darajo |
Hanti | Tilmaamid | Heerka | |
Awood galinta magaca anode-ka | F 1 | F 2 | IEC 60613 |
21kW (50/60Hz) | 42.5kW (50/60Hz) | ||
Awood kaydinta kulaylka Anode | 100 kJ (140kHU) | IEC 60613 | |
Awoodda qaboojinta ugu badan ee anode | 475W | ||
Awoodda kaydinta kulaylka | 900kJ | ||
Max. kulaylka joogtada ah oo aan lahayn Hawo-wareeg | 180W | ||
Maaddada anodeQalabka dahaarka sare ee Anode | Rhenium-Tungsten-TZM(RTM) Rhenium-Tungsten-(RT) | ||
Xagasha bartilmaameedka (Tixraac: dhidibka tixraaca) | 16 ° | IEC 60788 | |
Isku dhafka tuubada raajada sifaynta dabiiciga ah | 1.5 mm Al / 75kV | IEC 60601-1-3 | |
Barta xudunta u ah qiimaha magaca (yada) | F1 (fiiri yar) | F2 (fiirin weyn) | IEC 60336 |
1.0 | 2.0 | ||
tuubada raajada danab magaceeduShucaaca Fluoroscopic | 125kV 100kV | IEC 60613 | |
Xogta kululaynta cathode Max. hadda danabka ugu badan | ≈ / AC, <20 kHz | ||
F1 | F 2 | ||
5.1A ≈5.8~7.8V | 5.1 A ≈7.7~10.4 V | ||
Shucaaca ka daadanaya 150 kV/3mA masaafo 1m ah | ≤1.0mGy/h | IEC60601-1-3 | |
Goobta shucaaca ugu badan | 573×573mm xaga SID 1m | ||
Culayska isku-ururinta tuubada raajada | Qiyaastii 18 kg |
Xaddid | Xadka Hawlgalka | Xadka Gaadiidka iyo Kaydinta |
Heerkulka deegaanka | Laga bilaabo 10℃ilaa 40℃ | Laga bilaabo - 20℃to 70℃ |
Qoyaanka qaraabada | ≤75% | ≤93% |
Cadaadiska Barometric | Laga soo bilaabo 70kPa ilaa 106kPa | Laga soo bilaabo 70kPa ilaa 106kPa |
1-phase stator
Barta tijaabada | C-M | C-A |
iska caabin dabaylaha | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
Ugu badnaan. | 230V± 10% | |
Ku talin in danab shaqaynayo (kor u kac) | 160V± 10% | |
Voltaga bareegga | 70VDC | |
Korantada orod-ku-soo-gaadhista | 80Vrms | |
Danab ku shaqeeya fluoroscopy | 20V-40Vrms | |
Wakhtiga kor-u-qaadista (waxay kuxirantahay nidaamka bilowga) | 1.2s |
Digniin ku saabsan is dhexgalka raajada Generator
1.Guryaha Burburka
Weligaa ha gelinin in ka badan awoodda la qiimeeyay isku xirka tuubada raajada
Haddi awooda wax galinta ay ka badato qeexida tuubada, waxa laga yaaba in ay keento anode-ku in uu kululaado, muraayada tuubada in ay burburto, ugu danbayna waxa ay sababi kartaa dhibaatooyin halis ah oo ay sabab u tahay kororka xad-dhaafka ah ee ay keento uumiga saliida ee golaha guryeynta. Marka lagu jiro xaalad halis ah oo guryuhu dillaaco culeys xad dhaaf ah awgiis, badqabka kulaylka badqabka ayaa laga yaabaa inuusan awoodin inuu ilaaliyo tuubada raajada, xitaa haddii uu shaqeynayo.
*Qaybaha daboolaya guryaha ayaa dilaaca
*Dhaawaca bini'aadamka oo ay ku jiraan gubasho ay sabab u tahay baxsashada saliidda kulul.
*Shil dab oo ka dhashay bartilmaameedka anode ololaya.
Soo saaraha raajada waa inuu lahaadaa shaqo ilaalin ah oo maamusha awoodda wax gelinta si ay ugu jirto qeexitaanka tuubada.
2.Shaqo koronto
Si looga fogaado khatarta shoogga koronto, qalabkan waa in lagu xidhaa oo keliya sahayda leh dhulka difaaca.
3.Lama ogola wax ka beddelka qalabkan!!
Ka digtoonow in lagu dhex xidho Generator X-ray
1.Over Rating
Tamar badan oo ku jirta hal tallaal ayaa laga yaabaa inay keento isku-xirnaanta tuubada raajada
2.Shaandhaynta Joogtada ah
Xeerarka sharciga ayaa qeexaya wadarta guud ee shaandhaynta loo baahan yahay iyo masaafada ugu yar ee u dhaxaysa barta diiradda X-ray iyo jidhka bini'aadamka.
They waa in loo hoggaansamo sharciga.
3.Badbaadada kulaylka Badbaadada
Isku-xidhka tubbada raajada ayaa leh badqabka kulaylka badbaadada si ay u mamnuucdo awood gelin dheeraad ah marka guriga tuubada uu gaaro heerkulka(80℃)fur-furan.
Furaha laguma talinayo in lagu xidho gariiradda stator ee wareegyada taxanaha ah.
Xataa haddii daaraduhu shaqeeyo, waligaa ha damin tamarta nidaamka. Cutubka qaboojinta waa in la hawlgeliyaa haddii lagu isticmaalo nidaamka.
4.Xaaladda lama filaanka ah
Isku-duwayaasha tubbada raajada waxay si lama filaan ah u shaqayn karaan ama u fashilmi karaan si lama filaan ah, taasoo abuuraysa khatarta dhibaatooyin halis ah. Waa muhiim in la sameeyo qorshe degdeg ah si looga hortago loona xalliyo dhibaato kasta oo ka iman karta khatartan.
5.Codsi Cusub
Haddii aad qorshaynayso inaad alaabtan ku isticmaasho codsi cusub oo aan lagu sheegin dukumeentigan, ama haddii aad qorshaynayso inaad isticmaasho nooc ka duwan koronto-dhaliyaha X-ray, fadlan nala soo xidhiidh si aad u xaqiijiso ku habboonaanta iyo helitaanka.
1 .X-ray Shucaacailaalinta
Alaabtani waxay buuxinaysaa shuruudaha IEC 60601-1-3.
Isku xirka tuubada raajada ayaa shaqada siida shucaaca raajada.
Saamaynta jireed ee laxidhiidha waxay u horseedi kartaa waxyeelo bukaanka, soosaarida nidaamku waa inay qaadaa ilaalin habboon si looga fogaado shucaaca ionization.
2.Dielectric 0il
Isku-xidhka tuubada raajada ayaa leh dielectric 0il oo ka kooban xasilloonida korantada sare. Maadaama ay sun u tahay caafimaadka aadanaha,haddii ay soo baxdo aagga aan xaddidnayn,waa in loo tuuraa sida soo socota xeerka deegaanka.
3 .Hawlgalka Jawiga
Isku-xidhka tubbada raajada looma oggola in lagu isticmaalo jawiga gaasta gubanaysa ama daxalaysa.
4.Hagaaji Tubada Hadda
Iyadoo ku xiran xaaladaha shaqada,waxaa laga yaabaa in la beddelo sifooyinka filaha.
Isbeddelkan ayaa laga yaabaa inuu u saro kaco heerka sare ee soo-gaadhista tuubada raajada.
Si looga hortago in isku dhafka tuubada raajada ay waxyeelo gaarto,si joogto ah u hagaaji tuubada hadda socota.
Marka laga soo tago marka tuubada raajada ay leedahay dhib la'aanlisticmaalka waqtiga,hagaajinta hadda tuubada ayaa loo baahan yahay.
5.X-ray Tube Heer kulka Guryaha
Ha taaban tuubada raajada ee guriga wax yar uun ka dib qalliinka sababtoo ah heerkulka sare.
Joog tuubada raajada si loo qaboojiyo.
6Xadka hawlgalka
Kahor isticmaalka,fadlan xaqiiji in xaalada deegaanku ay ku dhex jirto Iimits.
7.Wixii cillad ah
P1ease la xidhiidh SAILRAY isla markiiba,Haddii wax cillad ah oo ka mid ah isku dhafka tuubada raajada la dareemo.
8.Qaadis
Isku-xidhka tubbada raajada iyo sidoo kale tubbada waxa ku jira walxo ay ka mid yihiin saliid iyo biro culus kuwaas oo deegaan ahaan u wanaagsan oo si habboon loo qubo si waafaqsan xeerarka sharciga qaranka ee jira waa in la hubiyaa. aqoonta farsamada ee loo baahan yahay oo dib u soo celin doonta tuubada raajada si loo tuuro.
Fadlan la xidhiidh adeegga macaamiisha ujeedadan.
Haddi(A) Barta Focal Yar
Haddi(A) Barta Focal Weyn
Xaaladaha: Voltage Tube Saddex- Waji
Soo noqnoqda Awoodda Stator 50Hz/60Hz
IEC60613
Tilmaamaha kulaylka Guriyeynta
SRMWHX7010A
SRMWHX7010B
Isku shaandheynta iyo Qaybta Isku-tallaabta ee Dekedda
Xidhiidhiyaha Rotor
Tirada Dalbashada Ugu Yar: 1pc
Qiimaha: gorgortanka
Faahfaahinta Baakadaha: 100pcs kartoonkiiba ama loo habeeyey iyadoo loo eegayo tirada
Waqtiga Bixinta: 1 ~ 2 toddobaad iyadoo loo eegayo tirada
Shuruudaha Lacag-bixinta: 100% T/T hore ama WESTERN UNION
Awood bixinta: 1000pcs / bishii