Sharaxaad Gaaban:

Astaamaha
 La jaanqaadi kara qalabka baaritaanka raajada X-ray iyadoo la adeegsanayo danab tuubo 150kV ah, oo ay ku jiraan nidaamyada dijitaalka ah ee DR iyo nidaamyada caadiga ah
Goobta shucaaca X-ray waa leydi
 U hoggaansan heerarka qaranka iyo warshadaha ee khuseeya
 Cabbir yar
Kalsooni sare iyo waxqabad kharash sare leh
Waxay isticmaashaa hal lakab, laba qaybood oo caleemo rasaas ah iyo naqshad gaar ah oo ilaalin gudaha ah si ay u xirto raajada X-ray.
 Hagaajinta goobta shucaaca waa mid gacanta lagu sameeyo, si joogto ah ayaa loo hagaajin karaa
 Goobta iftiinka ee la arki karo waxay qaadataa nalalka LED-ka
 Wareeg dib u dhac ah oo ku dhex jira ayaa si toos ah u damiya laambadda 30 ilbiriqsi ka dib marka la hawlgeliyo, waxaana sidoo kale la heli karaa ikhtiyaar gacan-ku-dhigis ah oo lagu damin karo nalka inta lagu jiro shaqada. Astaamahan waxaa loogu talagalay inay kordhiyaan cimriga nalka oo ay yareeyaan isticmaalka tamarta.


Faahfaahinta Badeecada

Shuruudaha Lacag-bixinta iyo Dhoofinta:

Calaamadaha Alaabta

Xuduudaha farsamada ee ugu muhiimsan iyo tilmaamayaasha

Daadinta raajada X-ray: <1mGy/saacaddii (150kV, 4mA)
Masaafadan waxaa lagu hagaajin karaa iyadoo loo eegayo tuubada gaarka ah ee X-ray-ga ee la isticmaalo. Masaafada caadiga ah waa 60mm laga bilaabo diiradda tuubada X-ray-ga ilaa dusha sare ee ku rakiban xadka alwaaxa.
Goobta ugu badan ee shucaaca: 43cmX43cm (SID=1m)
Goobta shucaaca ugu yar: <5cmX5cm (SID=1m)
Iftiinka goobta iftiinka ee la arki karo: >140lux (SID = 1m)
 Joogtaynta goobta iftiinka leh: <2%@SID
Shaandhaynta dabiiciga ah: 1mmAl/75kV
Qalabka korontada: 24VAC/50W ama 24VDC/50W
Cabbirka: 185mm × 198mm × 145mm (dherer × ballac × dherer)
Miisaanka: 6.2kg

Ikhtiyaari ah:
 Shaandhada dheeraadka ah ee dibadda
Isku-xirka korontada gaarka ah
Isku-xirka kubbadda tuubada gaarka ah
Helaha laysarka hal-geesoodka ah

Xuduudaha farsamada

Danabka ugu Badan

150KV

Heerka ugu badan ee daboolida goobta X-ray

440mm × 440mm (SID = 100cm)

Iftiinka celceliska ee goobta iftiinka

>160 raaxo

Saamiga isbarbardhigga geeska

>4:1

Shuruudaha korontada ee laambadda saadaasha

24V/150W

Muddada goobta X-ray-ga dhalaalaya ee Hal mar

30S

Masaafada u dhaxaysa Barta Focal ee tuubada X-ray ilaa meesha la saaro ee SID-ka isku xidhka (mm) (ikhtiyaar)

60

Sifeynta (Dabiiciga ah) 75kV

1mmAl

Shaandhaynta (Dheeraad ah)

Ikhtiyaar dibadda ah

Habka xakamaynta

Buug-gacmeed

Matoorka wadista

--

Xakamaynta Mootada

--

Ogaanshaha booska

--

Awoodda gelinta

AC24V

Cajalad cabbir ah (SID)

Qaabeynta Caadiga ah

Tilmaamaha dhexe ee laysarka

ikhtiyaari ah

Cabbirka (mm) (D × L × H)

185×198×145

Miisaanka (Kg)

6.8

Codsiyada

Qalabkan x-ray collimator-ka wuxuu ku habboon yahay danabka tuubada 150kV, qalabka DR digital iyo qalabka baaritaanka raajada caadiga ah.


  • Kii hore:
  • Xiga:

  • Tirada Dalabka Ugu Yar: 1pc

    Qiimaha: Gorgortanka

    Faahfaahinta Baakadaha: 100pcs kartoonkiiba ama loo habeeyey iyadoo loo eegayo tirada

    Waqtiga Bixinta: 1 ~ 2 toddobaad iyadoo loo eegayo tirada

    Shuruudaha Lacag-bixinta: 100% T/T horay loo sii bixiyay ama WESTERN UNION

    Awoodda Bixinta: 1000pcs/bishii