Collimator-ka Caafimaadka ee X-ray Collimator-ka ee Tooska ah ee X-ray Collimator SR301

Collimator-ka Caafimaadka ee X-ray Collimator-ka ee Tooska ah ee X-ray Collimator SR301

Collimator-ka Caafimaadka ee X-ray Collimator-ka ee Tooska ah ee X-ray Collimator SR301

Sharaxaad Gaaban:

Astaamaha
Ku habboon danabka tuubada 150kV, qalabka baaritaanka raajada DR iyo kuwa caadiga ah
Goobta shucaaca X-ray waa leydi
 U hoggaansan heerarka qaranka iyo warshadaha ee khuseeya
Kalsooni sare iyo waxqabad kharash sare leh
 Lakabyo laba jibbaaran iyo laba qaybood oo caleemo rasaas ah iyo qaab-dhismeed gaar ah oo gudaha ah ayaa loo isticmaalaa in lagu ilaaliyo raajooyinka X-ray. Caleenta rasaasta sare waxay geli kartaa daaqadda tuubada raajada X-ray, taasoo si wax ku ool ah u ilaalin karta fallaaraha kala firdhisan.
 Hagaajinta goobta shucaaca waa mid gacanta lagu sameeyo, si joogto ah ayaa loo hagaajin karaa
 Goobta iftiinka ee la arki karo waxay qaadataa nalalka LED-ka ee dhalaalaya sare leh
 Wareegga dib u dhigista gudaha ayaa si toos ah u damin kara nalka 30 ilbiriqsi ka dib iftiin, wuxuuna gacanta ku damin karaa nalka inta lagu jiro xilliga iftiinka si loo dheereeyo cimriga nalka loona badbaadiyo tamarta.
Xiriir farsamo oo ku habboon oo lagu kalsoonaan karo oo leh tuubada X-ray, oo si fudud loo hagaajin karo


Faahfaahinta Badeecada

Shuruudaha Lacag-bixinta iyo Dhoofinta:

Calaamadaha Alaabta

Xuduudaha farsamada ee ugu muhiimsan iyo tilmaamayaasha

Daadinta raajada X-ray: <1mGy/saacaddii (150kV, 4mA)
Masaafada u dhaxaysa diiradda tuubada X-ray ilaa dusha sare ee ku rakiban alwaaxda: 60mm (waxaa lagu hagaajin karaa iyadoo loo eegayo tuubooyinka kala duwan)
Goobta ugu badan ee shucaaca: 48cmX48cm (SID=1m)
Goobta shucaaca ugu yar: <5cmX5cm (SID=1m)
Iftiinka goobta iftiinka ee la arki karo: >140lux (SID = 1m)
 Joogtaynta goobta iftiinka leh: <2%@SID
Shaandhaynta dabiiciga ah: 1mmAl/75kV
Qalabka korontada: 24VAC/50W ama 24VDC/2A
Cabbirka: 200mm × 230mm × 170mm (dherer × ballac × dherer)
Miisaanka: 8.4kg

Ikhtiyaari ah:
 Shaandhada dheeraadka ah ee dibadda
Isku-xirka korontada gaarka ah
Isku-xirka kubbadda tuubada gaarka ah
Helaha laser-ka ee hal-erey ah (Fasalka 1aad)

Xuduudaha farsamada

Danabka ugu Badan

150KV

Heerka ugu badan ee daboolida goobta X-ray

480mm × 480mm (SID = 100cm)

Iftiinka celceliska ee goobta iftiinka

>160 raaxo

Saamiga isbarbardhigga geeska

>4:1

Shuruudaha korontada ee laambadda saadaasha

24V AC/150W

Muddada goobta X-ray-ga dhalaalaya ee Hal mar

30S

Masaafada u dhaxaysa Barta Focal ee tuubada X-ray ilaa meesha la saaro ee SID-ka isku xidhka (mm) (ikhtiyaar)

60

Sifeynta (Dabiiciga ah) 75kV

1mmAl

Shaandhaynta (Dheeraad ah)

Ikhtiyaar dibadda ah

Habka xakamaynta

Buug-gacmeed

Matoorka wadista

--

Xakamaynta Mootada

--

Ogaanshaha booska

--

Awoodda gelinta

AC24V

Cajalad cabbir ah (SID)

Qaabeynta Caadiga ah

Tilmaamaha dhexe ee laysarka

ikhtiyaari ah

Cabbirka (mm) (D × L × H)

200 × 230 × 170

Miisaanka (Kg)

8.4

Codsiyada

Collimator-kani wuxuu ku habboon yahay danabka tuubada 150kV, qalabka baaritaanka DR-ka iyo kuwa caadiga ah ee X-ray.


  • Kii hore:
  • Xiga:

  • Tirada Dalabka Ugu Yar: 1pc

    Qiimaha: Gorgortanka

    Faahfaahinta Baakadaha: 100pcs kartoonkiiba ama loo habeeyey iyadoo loo eegayo tirada

    Waqtiga Bixinta: 1 ~ 2 toddobaad iyadoo loo eegayo tirada

    Shuruudaha Lacag-bixinta: 100% T/T horay loo sii bixiyay ama WESTERN UNION

    Awoodda Bixinta: 1000pcs/bishii

    Halkan ku qor fariintaada oo noo soo dir