Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka X-ray Collimator SR102

Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka X-ray Collimator SR102

Buug-gacmeedka X-ray-ga Caafimaadka ee Collimator-ka X-ray Collimator SR102

Sharaxaad Gaaban:

Astaamaha
Ku habboon qalabka baaritaanka raajada X-ray ee caadiga ah oo leh danab tuubo ah oo ah 150kV
Aagga ay sawirtay raajo X-ray waa leydi.
 Badeecadani waxay u hoggaansan tahay heerarka qaranka iyo warshadaha ee khuseeya
 Cabbir yar
Waxqabad la isku halleyn karo, kharash-ool ah.
Isticmaalka hal lakab iyo laba qaybood oo caleemo rasaas ah iyo qaab-dhismeed gaar ah oo ilaalin gudaha ah si loo ilaaliyo raajada X-ray
 Hagaajinta goobta shucaaca waa mid gacanta lagu sameeyo, goobta shucaaca waa mid si joogto ah loo hagaajin karo
 Goobta iftiinka ee muuqata waxay qaadataa nalalka LED-ka ee dhalaalaya oo heer sare ah, kuwaas oo leh cimri dheer oo adeeg ah.
 Wareegga dib u dhigista gudaha ayaa si toos ah u damin kara nalka 30 ilbiriqsi ka dib iftiin, wuxuuna gacanta ku damin karaa nalka inta lagu jiro xilliga iftiinka si loo dheereeyo cimriga nalka loona badbaadiyo tamarta.
Xiriirka farsamada ee u dhexeeya badeecadan iyo tuubada X-ray waa mid ku habboon oo lagu kalsoonaan karo, hagaajintana waa mid fudud


Faahfaahinta Badeecada

Shuruudaha Lacag-bixinta iyo Dhoofinta:

Calaamadaha Alaabta

Xuduudaha farsamada ee ugu muhiimsan iyo tilmaamayaasha

Daadinta raajada X-ray: <1mGy/saacaddii (150kV, 4mA)
Masaafada u dhaxaysa diiradda tuubada X-ray ilaa dusha sare ee ku rakiban alwaaxda: 60mm (waxaa lagu hagaajin karaa iyadoo loo eegayo tuubooyinka kala duwan)
 Joogtaynta goobta iftiinka leh: <2%@SID
Shaandhaynta dabiiciga ah: 1mmAl/75kV

Ikhtiyaari ah:
Xulashooyinka Shaandhaynta Dibadda ee La Hagaajiyay
Isku-xirka korontada gaarka ah
Isku-xirka kubbadda tuubada gaarka ah

Xuduudaha farsamada

Danabka ugu Badan

150KV

Heerka ugu badan ee daboolida goobta X-ray

440mmx440mm (SID=100cm)

Iftiinka celceliska ee goobta iftiinka

>160 raaxo

Saamiga isbarbardhigga geeska

>4:1

Shuruudaha korontada ee laambadda saadaasha

24V/100W

Muddada goobta X-ray-ga dhalaalaya ee Hal mar

30S

Masaafada u dhaxaysa Barta Focal ee tuubada X-ray ilaa meesha la saaro ee SID-ka isku xidhka (mm) (ikhtiyaar)

60

Sifeynta (Dabiiciga ah) 75kV

1mmAl

Shaandhaynta (Dheeraad ah)

Ikhtiyaar dibadda ah

Habka xakamaynta

Buug-gacmeed

Matoorka wadista

--

Xakamaynta Mootada

--

Ogaanshaha booska

--

Awoodda gelinta

AC24V

Cajalad cabbir ah (SID)

Qaabeynta Caadiga ah

Tilmaamaha dhexe ee laysarka

--

Cabbirka (mm) (D × L × H)

223x185x87

Miisaanka (Kg)

5.5

Qaab-dhismeedka

Codsiyada

Konfilatoorkan raajada ayaa ku habboon qalabka ogaanshaha raajada caadiga ah ee leh danab tuubo ah oo ah 150kV, DR.


  • Kii hore:
  • Xiga:

  • Tirada Dalabka Ugu Yar: 1pc

    Qiimaha: Gorgortanka

    Faahfaahinta Baakadaha: 100pcs kartoonkiiba ama loo habeeyey iyadoo loo eegayo tirada

    Waqtiga Bixinta: 1 ~ 2 toddobaad iyadoo loo eegayo tirada

    Shuruudaha Lacag-bixinta: 100% T/T horay loo sii bixiyay ama WESTERN UNION

    Awoodda Bixinta: 1000pcs/bishii

    Halkan ku qor fariintaada oo noo soo dir